EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of the Occupational Radiation Exposure from C-arm Fluoroscopy during Common Orthopaedic Surgical Procedures: DAP-based Dose Simulation Method

Sudeeptha Liyanage, Hiran Tharanga Wickramarathne, Udari Kalpana, Badra Hewavithana

Ceylon Medical Journal · 31.12.2022 · 67 (4) · 164-168

DOI: 10.4038/cmj.v67i4.9745 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ceylon Medical Journal, online erschienen am 31.12.2022. Verfasst von Sudeeptha Liyanage und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiography/ Radiotherapy, Faculty of Allied Health Sciences, University of Peradeniya, Sri Lanka. Hauptthemen laut MEDLINE: Orthopedics, Radiation Exposure. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of fluoroscopy in orthopaedic operations cause a risk for radiation-induced carcinoma for the theatre staff. Thus, the aim of the study was to calculate the occupational radiation doses (ORD) for the orthopaedic theatre crew during fluoroscopy-guided surgeries and to compare them with accepted reference standards. The end Dose Area Products (DAP) were recorded for the commonest 3 types of orthopaedic surgeries by observing 50 surgeries in 2 hospital. The ORD for 4 types of theatre personnel were simulated using. ORDs were statistically analyzed. The calculated mean annual dosage was 0.977mSv. All dosages fell significantly below the reference threshold (20mSv) or less annually. The mean doses that each member of the staff received during the same surgery was different from one another. The orthopaedic surgeon predominantly receives the highest ORD (88.89%), whilst the anaesthetist receives the least (77.78%).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OrthopedicsRadiation ExposureHumansFluoroscopy

Autor:innen und Institutionen

  • Department of Radiography/ Radiotherapy, Faculty of Allied Health Sciences, University of Peradeniya, Sri Lanka.
  • Department of Radiology, Faculty of Medicine, University of Peradeniya, Sri Lanka.

Zitieren

APA

Liyanage, S., Wickramarathne, H. T., Kalpana, U., & Hewavithana, B. (2022). Evaluation of the Occupational Radiation Exposure from C-arm Fluoroscopy during Common Orthopaedic Surgical Procedures: DAP-based Dose Simulation Method. Ceylon Medical Journal, 67(4), 164-168. https://doi.org/10.4038/cmj.v67i4.9745

Vancouver

Liyanage S, Wickramarathne HT, Kalpana U, Hewavithana B. Evaluation of the Occupational Radiation Exposure from C-arm Fluoroscopy during Common Orthopaedic Surgical Procedures: DAP-based Dose Simulation Method. Ceylon Medical Journal. 2022;67(4):164-168. doi:10.4038/cmj.v67i4.9745

BibTeX
@article{Liyanage2022,
  author = {Liyanage, Sudeeptha and Wickramarathne, Hiran Tharanga and Kalpana, Udari and Hewavithana, Badra},
  title = {Evaluation of the Occupational Radiation Exposure from C-arm Fluoroscopy during Common Orthopaedic Surgical Procedures: DAP-based Dose Simulation Method},
  journal = {Ceylon Medical Journal},
  year = {2022},
  volume = {67},
  number = {4},
  pages = {164--168},
  doi = {10.4038/cmj.v67i4.9745}
}
Kostenlos starten →