EUVIMEDEUVIMED entdecken
Fallbericht

Quantitative Pupillometry Obtained During Cardiac Arrest: A Case Report

Kathrina Siaron, Lilian Otieno, Lindsay M Riskey, Sharla Houston, DaiWai M Olson, Emerson B Nairon

Critical Care Nurse · 01.06.2026 · 46 (3) · 11-15

DOI: 10.4037/ccn2026662 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Critical Care Nurse, erschienen am 01.06.2026. Verfasst von Kathrina Siaron und 5 weiteren Autor:innen. Beteiligte Einrichtung: Kathrina Siaron is an assistant nurse manager, Department of Nursing, University of Texas Southwestern Medical Center, Dallas, Texas. Hauptthemen laut MEDLINE: Heart Arrest, Reflex, Pupillary. Die Arbeit nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Quantitative pupillometry is increasingly used to assess patients’ neurologic function quickly and accurately. This case report discusses the feasibility of collecting quantitative pupillometry data for patients experiencing cardiac arrest, the potential value of these data, and limitations of quantitative pupillometry. Clinical Findings An 83-year-old woman was admitted to the cardiac catheterization laboratory for coronary angiography and percutaneous coronary intervention. She experienced cardiac arrest during the procedure, and the rapid response team was deployed. Diagnosis Coronary artery disease with angina was present upon admission. The patient was admitted with the intent to perform percutaneous coronary intervention of the left anterior descending coronary artery.

Interventions

During the cardiac arrest and while staff members were performing chest compressions, rapid response team nurses obtained quantitative pupillometry readings to assess pupil function. Outcomes The quantitative pupillometry readings obtained from the left and right eyes suggested that neurologic function was abnormal but still present. The main challenges associated with performing quantitative pupillometry during a cardiac arrest are overcrowding of essential personnel at the head of bed and finding an appropriate time to obtain readings without compromising life-sustaining interventions.

Conclusion

Using quantitative pupillometry to assess pupil function during cardiac arrest is feasible when performed by nurses. This report may facilitate pupil assessment during cardiac arrest and provide new insights into cerebral perfusion as a biomarker of recovery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart ArrestReflex, PupillaryHumansFemaleAged, 80 and overPercutaneous Coronary InterventionCardiopulmonary ResuscitationCoronary Angiography

Autor:innen und Institutionen

  • Kathrina Siaron is an assistant nurse manager, Department of Nursing, University of Texas Southwestern Medical Center, Dallas, Texas.
  • Lilian Otieno is an assistant nurse manager, Department of Nursing, University of Texas Southwestern Medical Center.
  • Lindsay M. Riskey is a registered nurse II, Department of Nursing, University of Texas Southwestern Medical Center.
  • Sharla Houston is a registered nurse II, Department of Nursing, University of Texas Southwestern Medical Center.
  • DaiWai M. Olson is a professor, Department of Neurology, University of Texas Southwestern Medical Center. He is the editor of the Journal of Neuroscience Nursing.
  • Emerson B. Nairon is a clinical research coordinator, Department of Neurology, University of Texas Southwestern Medical Center.

Zitieren

APA

Siaron, K., Otieno, L., Riskey, L. M., Houston, S., Olson, D. M., & Nairon, E. B. (2026). Quantitative Pupillometry Obtained During Cardiac Arrest: A Case Report. Critical Care Nurse, 46(3), 11-15. https://doi.org/10.4037/ccn2026662

Vancouver

Siaron K, Otieno L, Riskey LM, Houston S, Olson DM, Nairon EB. Quantitative Pupillometry Obtained During Cardiac Arrest: A Case Report. Critical Care Nurse. 2026;46(3):11-15. doi:10.4037/ccn2026662

BibTeX
@article{Siaron2026,
  author = {Siaron, Kathrina and Otieno, Lilian and Riskey, Lindsay M and Houston, Sharla and Olson, DaiWai M and Nairon, Emerson B},
  title = {Quantitative Pupillometry Obtained During Cardiac Arrest: A Case Report},
  journal = {Critical Care Nurse},
  year = {2026},
  volume = {46},
  number = {3},
  pages = {11--15},
  doi = {10.4037/ccn2026662}
}
Kostenlos starten →