EUVIMEDEUVIMED entdecken
Crossref

Using Stethoscope Hygiene Barriers to Reduce Central Catheter–Associated Bloodstream Infection Rates

Naomi Ragsdale, Wendy Simpson, W Frank Peacock

Critical Care Nurse · 01.10.2026 · 46 (5) · 61-66

DOI: 10.4037/ccn2026637 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Critical Care Nurse, erschienen am 01.10.2026. Verfasst von Naomi Ragsdale und 2 weiteren Autor:innen. Beteiligte Einrichtung: Naomi Ragsdale is an infection preventionist, Lt. Col. Luke Weathers, Jr VA Medical Center, Memphis, Tennessee. Hauptthemen laut MEDLINE: Catheter-Related Infections, Stethoscopes, Catheterization, Central Venous, Infection Control. Die Arbeit nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Central line [catheter]–associated bloodstream infections (CLABSIs) represent a significant mortality risk. Local Problem Due to a significant increase in CLABSI rate, a new CLABSI prevention bundle strategy was evaluated to determine whether it changed the CLABSI rate.

Methods

A before and after quality improvement project was performed in an 18-bed intensive care unit from March 1, 2021, to March 1, 2025. A CLABSI prevention bundle was implemented; CLABSI rates were compared for 1 year before to 3 years after intervention implementation. Additionally, clinician satisfaction surveys were collected.

Interventions

The implemented bundle consisted of (1) replacement of disposable stethoscopes with touch-free, aseptic stethoscope diaphragm cover dispensers (DiskCover System, AseptiScope, Inc) in each intensive care unit room, and (2) requiring a chlorhexidine-impregnated dressing for all central catheters, with standardization and reeducation of bedside staff on central catheter dressing changes.

Results

Of 5226 intensive care unit patients, the mean CLABSI rate was 4.42 (95% CI, 2.93-5.91) infections per 1000 patient central catheter days during the year before implementation, which decreased to 0.70 (95% CI, –1.21 to 2.61) in the 3 years after implementation. Clinicians reported the new strategy was easy to use and superior to disposable stethoscopes.

Conclusion

A CLABSI bundle that included touch-free, aseptic stethoscope hygiene barriers and chlorhexidine-impregnated dressings was highly effective at decreasing the CLABSI rate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter-Related InfectionsStethoscopesCatheterization, Central VenousInfection ControlHygieneCritical Care NursingHumansFemaleMaleIntensive Care UnitsMiddle AgedQuality ImprovementAged

Autor:innen und Institutionen

  • Naomi Ragsdale is an infection preventionist, Lt. Col. Luke Weathers, Jr VA Medical Center, Memphis, Tennessee.
  • Wendy Simpson is an infection preventionist, Lt. Col. Luke Weathers, Jr VA Medical Center.
  • W. Frank Peacock is a professor, Emergency Medicine, Emergency Department, Baylor College of Medicine, Houston, Texas, and chief medical officer, AseptiScope, Inc, San Diego, California.

Zitieren

APA

Ragsdale, N., Simpson, W., & Peacock, W. F. (2026). Using Stethoscope Hygiene Barriers to Reduce Central Catheter–Associated Bloodstream Infection Rates. Critical Care Nurse, 46(5), 61-66. https://doi.org/10.4037/ccn2026637

Vancouver

Ragsdale N, Simpson W, Peacock WF. Using Stethoscope Hygiene Barriers to Reduce Central Catheter–Associated Bloodstream Infection Rates. Critical Care Nurse. 2026;46(5):61-66. doi:10.4037/ccn2026637

BibTeX
@article{Ragsdale2026,
  author = {Ragsdale, Naomi and Simpson, Wendy and Peacock, W Frank},
  title = {Using Stethoscope Hygiene Barriers to Reduce Central Catheter–Associated Bloodstream Infection Rates},
  journal = {Critical Care Nurse},
  year = {2026},
  volume = {46},
  number = {5},
  pages = {61--66},
  doi = {10.4037/ccn2026637}
}