Ultrasonographic Pupil Assessment in Patients With Severe Traumatic Brain Injury
American Journal of Critical Care · 01.11.2026 · 35 (6) · 455-462
DOI: 10.4037/ajcc2026776 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Critical Care, online erschienen am 01.11.2026. Verfasst von Qian Shi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Qian Shi is a staff nurse, Intensive Care Unit, Nanjing Drum Tower Hospital, Nanjing, China. Hauptthemen laut MEDLINE: Brain Injuries, Traumatic, Pupil. Die Arbeit nennt 26 Literaturangaben. Gefördert von: Nanjing Health Science and Technology Development Project.
Abstract (Originalsprache)
Background
In patients with severe traumatic brain injury, accurate pupillary assessment is critical for neurological monitoring but is often hindered by periorbital edema, trauma, or dressings that preclude direct visualization.
Objective
To validate the feasibility and accuracy of ultrasonographic pupil assessment performed through the closed eyelid as an alternative to direct pupillometry in patients with traumatic brain injury.
Methods
This prospective study enrolled 45 intensive care unit patients (36 male; mean [SD] age, 67.1 [12.9] years). Both direct pupillometry and ultrasonographic pupil assessment were sequentially completed within a 3-minute interval under standardized low-light conditions for both eyes. Direct pupillometry involved video recording of the exposed pupil with a calibrated reference scale. Ultrasonographic pupil assessment was performed by using a high-frequency linear probe placed on the closed eyelid. The primary outcome was the agreement between methods for calculating the percentage of pupillary constriction. Secondary outcomes included agreement on resting and minimum pupil diameters.
Results
Ultrasonographic pupil assessment showed excellent agreement with direct pupillometry for percent pupillary constriction (median [IQR] difference, 0.44% [−2.78% to 2.83%]; Wilcoxon P ≥ .48). Bland-Altman analysis showed narrow limits of agreement. Strong correlations were also noted for resting and minimum pupil diameters (0.6 ≤ r2 ≤ 0.873).
Conclusion
Ultrasonographic pupil assessment is a reliable and accurate method for objective pupillary evaluation when direct visualization is obstructed. By enabling quantitative measurement of the pupillary light reflex through the closed eyelid, ultrasonographic pupil assessment addresses an important monitoring gap in the management of patients with severe traumatic brain injury and periorbital swelling.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Qian Shi is a staff nurse, Intensive Care Unit, Nanjing Drum Tower Hospital, Nanjing, China.
- Rujing Bai is a ward nurse manager, Intensive Care Unit, Nanjing Drum Tower Hospital, Nanjing, China.
- Yan Xu is a ward nurse manager, Intensive Care Unit, Nanjing Drum Tower Hospital, Nanjing, China.
- Bo Feng is a chief nurse superintendent and deputy section manager, Intensive Care Unit, Nanjing Drum Tower Hospital, Nanjing, China.
- Ling Yuan is a chief nurse superintendent and deputy director, Nursing Department, Nanjing Drum Tower Hospital, Nanjing, China.
- Niannian Liu is a staff nurse, Intensive Care Unit, Nanjing Drum Tower Hospital, Nanjing, China.
Förderung
- Nanjing Health Science and Technology Development Project
Zitieren
APA
Shi, Q., Bai, R., Xu, Y., Feng, B., Yuan, L., Liu, N., & Dong, D. (2026). Ultrasonographic Pupil Assessment in Patients With Severe Traumatic Brain Injury. American Journal of Critical Care, 35(6), 455-462. https://doi.org/10.4037/ajcc2026776
Vancouver
Shi Q, Bai R, Xu Y, Feng B, Yuan L, Liu N, et al. Ultrasonographic Pupil Assessment in Patients With Severe Traumatic Brain Injury. American Journal of Critical Care. 2026;35(6):455-462. doi:10.4037/ajcc2026776
BibTeX
@article{Shi2026,
author = {Shi, Qian and Bai, Rujing and Xu, Yan and Feng, Bo and Yuan, Ling and Liu, Niannian and Dong, Danjiang},
title = {Ultrasonographic Pupil Assessment in Patients With Severe Traumatic Brain Injury},
journal = {American Journal of Critical Care},
year = {2026},
volume = {35},
number = {6},
pages = {455--462},
doi = {10.4037/ajcc2026776}
}
EUVIMED