Bioelectrical Impedance Analysis to Assess Energy Expenditure in Critically Ill Patients: A Cross-Sectional Study

Qingru Zheng, Feng Li, Wenqi Tang, Xiaoli Huang, Shuaijun Cao, Feng Ping, Yingchuan Li, Zuoyan Zhang, Weifeng Huang

American Journal of Critical Care · 2024

DOI: 10.4037/ajcc2024240 ↗

Kurz gefasst

Querschnittstudie in der Zeitschrift American Journal of Critical Care, 2024. Verfasst von Qingru Zheng und 8 weiteren Autor:innen. Beteiligte Einrichtung: Qingru Zheng is a nurse, Department of Critical Care Medicine, Shanghai Sixth People's Hospital, Shanghai, China. Hauptthemen laut MEDLINE: Critical Illness, Energy Metabolism, Calorimetry, Indirect, Electric Impedance. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Evaluating energy expenditure is important for establishing optimal goals for nutrition treatment. However, indirect calorimetry, the reference standard for measuring energy expenditure, is difficult to apply widely in clinical practice.

Objective

To test the consistency of bioelectrical impedance analysis (BIA) relative to indirect calorimetry for evaluating energy expenditure in critically ill patients.

Methods

A cross-sectional study of 140 critically ill adult patients was conducted. Within 24 hours of a patient being transferred to the intensive care unit, trained researchers assessed the patient’s energy expenditure by use of BIA and indirect calorimetry simultaneously. Consistency of the 2 measurements was detected by intraclass correlation coefficients with a 2-way random-effects model. Factors affecting consistency were analyzed.

Results

Median energy expenditure measured by indirect calorimetry was 1430.0 kcal/d (IQR, 1190.5–1650.8 kcal/d). Median energy expenditure measured by BIA was 1407.0 kcal/d (IQR, 1248.5–1563.5 kcal/d). The correlation coefficient between indirect calorimetry and BIA was 0.813 (95% CI, 0.748–0.862; P < .001). The consistency of the 2 measurements was lower in patients with comorbidities than in those without (P = .004).

Conclusions

Results of BIA were highly consistent with indirect calorimetry assessments of energy expenditure in critically ill patients. Few factors except comorbidity affect the accuracy of BIA when assessing energy expenditure. Therefore, as a low-cost, easy-to-use, and noninvasive method, BIA is a valuable clinical tool for assessing energy expenditure in critically ill patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Critical IllnessEnergy MetabolismCalorimetry, IndirectElectric ImpedanceHumansCross-Sectional StudiesMaleFemaleMiddle AgedAgedIntensive Care UnitsAdult

Autor:innen und Institutionen

  • Qingru Zheng is a nurse, Department of Critical Care Medicine, Shanghai Sixth People's Hospital, Shanghai, China.
  • Feng Li is a physician, Department of Critical Care Medicine, Shanghai Xuhui Central Hospital, Zhongshan-Xuhui Hospital, Fudan University, Shanghai, China. This work was completed while Li was at the Department of Criti…
  • Wenqi Tang is a head nurse, Department of Critical Care Medicine, Shanghai Sixth People's Hospital, Shanghai, China.
  • Xiaoli Huang is a physician, Department of Critical Care Medicine, Jinshan Branch of Shanghai Sixth People's Hospital, Shanghai, China.
  • Shuaijun Cao is a nurse, Department of Critical Care Medicine, Shanghai Sixth People's Hospital, Shanghai, China.
  • Feng Ping is a physician, Department of Critical Care Medicine, West China Hospital of Sichuan University, Sichuan, China.

Zitieren

APA

Zheng, Q., Li, F., Tang, W., Huang, X., Cao, S., Ping, F., Li, Y., Zhang, Z., & Huang, W. (2024). Bioelectrical Impedance Analysis to Assess Energy Expenditure in Critically Ill Patients: A Cross-Sectional Study. American Journal of Critical Care. https://doi.org/10.4037/ajcc2024240

Vancouver

Zheng Q, Li F, Tang W, Huang X, Cao S, Ping F, et al. Bioelectrical Impedance Analysis to Assess Energy Expenditure in Critically Ill Patients: A Cross-Sectional Study. American Journal of Critical Care. 2024. doi:10.4037/ajcc2024240

BibTeX
@article{Zheng2024,
  author = {Zheng, Qingru and Li, Feng and Tang, Wenqi and Huang, Xiaoli and Cao, Shuaijun and Ping, Feng and Li, Yingchuan and Zhang, Zuoyan and Huang, Weifeng},
  title = {Bioelectrical Impedance Analysis to Assess Energy Expenditure in Critically Ill Patients: A Cross-Sectional Study},
  journal = {American Journal of Critical Care},
  year = {2024},
  doi = {10.4037/ajcc2024240}
}
Kostenlos starten →