Deposition of Inconel 718 and Stellite 6 Coatings on Steel by Directed Energy Deposition and Evaluation of Cavitation Response under Ultrasonic Testing
Solid State Phenomena · 23.11.2026 · 396 · 25-36
DOI: 10.4028/p-z9fcc1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Solid State Phenomena, online erschienen am 23.11.2026. Verfasst von Denis Andrei Predu und 4 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben.
Abstract (Originalsprache)
Two coatings deposited on steel by directed energy deposition (DED) were exposed to ultrasonic cavitation under a single laboratory protocol. The Inconel 718 coating was deposited on an InssTek MX-Mini system using a laser power of 230 W, a travel speed of 550 mm/min, a 0.15 mm layer height, a 0.30 mm step-over and a powder feed rate of 1.0 g/min; a second series was deposited by the same process route from Stellite 6, a cobalt-based Co-Cr-W-C hardfacing alloy. Both series used the same plain-carbon steel substrate and the same cylindrical specimen geometry. Cylindrical specimens were exposed in distilled water on a piezoceramic vibratory apparatus at a frequency of 20 ± 0.03 kHz, a vibration amplitude of 50 µm and a water temperature of 22 ± 1 °C, for a total attack time of 165 min. For the Stellite 6 series, cumulative mass loss was recorded gravimetrically at eight intermediate intervals and described by with A = 0.12, B = 3.873 × 10⁻³ and an endpoint cumulative mass loss of 9.35 mg. The Inconel 718 series was characterized after exposure by optical observation, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). The eroded Inconel 718 surface showed a radial, flow-like morphology together with localized pits and shallow grooves, without macroscopic coating detachment in the examined fields. A representative EDS acquisition yielded 41.5 wt% Ni, 19.3 wt% Cr and 39.2 wt% Fe, normalized over three elements. The Ni-Cr signal confirms that the deposited layer was retained at the analyzed location, while the Fe level, more than twice the nominal content of Inconel 718, corresponds to a substrate dilution of the order of 20-25 % under a simple two-source mixing assumption. Deposition route, machine, substrate, specimen geometry and test conditions were common to the two series, although the Stellite 6 deposition ran under closed-loop laser-power control while the Inconel 718 parameters are reported at a fixed setting; the Stellite 6 data quantify the erosion kinetics of that common exposure, while the Inconel 718 data document damage morphology and near-surface chemistry. No quantitative resistance ranking between the two coatings is claimed, because gravimetric records were acquired only for the Stellite 6 series.
Zitieren
APA
Predu, D. A., Bordeașu, I., Sîrbu, N. A., Faur, R., & Luca, D. A. (2026). Deposition of Inconel 718 and Stellite 6 Coatings on Steel by Directed Energy Deposition and Evaluation of Cavitation Response under Ultrasonic Testing. Solid State Phenomena, 396, 25-36. https://doi.org/10.4028/p-z9fcc1
Vancouver
Predu DA, Bordeașu I, Sîrbu NA, Faur R, Luca DA. Deposition of Inconel 718 and Stellite 6 Coatings on Steel by Directed Energy Deposition and Evaluation of Cavitation Response under Ultrasonic Testing. Solid State Phenomena. 2026;396:25-36. doi:10.4028/p-z9fcc1
BibTeX
@article{Predu2026,
author = {Predu, Denis Andrei and Bordeașu, Ilare and Sîrbu, Nicuşor Alin and Faur, Raluca and Luca, Doru Alexandru},
title = {Deposition of Inconel 718 and Stellite 6 Coatings on Steel by Directed Energy Deposition and Evaluation of Cavitation Response under Ultrasonic Testing},
journal = {Solid State Phenomena},
year = {2026},
volume = {396},
pages = {25--36},
doi = {10.4028/p-z9fcc1}
}