EUVIMEDEUVIMED entdecken
Crossref

Carbon- and Platinum-Modified Co-Cr Alloys for Thin-Strut Stents

Takayuki Narushima, Sukma Suci Friandani, Tomoki Nakajima, Kyosuke Ueda, Ryoji Sahara, Alfirano Alfirano

Journal of Biomimetics, Biomaterials and Biomedical Engineering · 20.05.2026 · 72 · 21-29

DOI: 10.4028/p-khm0g9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomimetics, Biomaterials and Biomedical Engineering, online erschienen am 20.05.2026. Verfasst von Takayuki Narushima und 5 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Percutaneous coronary intervention (PCI) is a minimally invasive treatment for ischemic heart disease, commonly supported by balloon-expandable stents to prevent arterial restenosis. Stent materials must combine high ultimate tensile strength, high ductility, low 0.2% proof strength, high corrosion resistance, high X-ray visibility, and magnetic susceptibility close to that of human soft tissues. The Co-20Cr-15W-10Ni (mass%) alloy, standardized as ASTM F90 and commonly referred to as L605 is widely employed for this purpose. Recently, the demand for stents with smaller diameters and thinner struts has grown, as these significantly lower restenosis risk. Alloys for thin-strut stents therefore require exceptional mechanical and physical performance. This paper reviews the microstructures and mechanical and physical properties of the carbon- and Pt-modified Co-Cr-W-Ni alloys developed by our group. The Co-20Cr-15W-10Ni-0.2C (mass%) alloy achieved an excellent strength–ductility balance and a low 0.2% proof strength owing to the γ-stabilizing effect of carbon. First-principles calculations further revealed that carbon addition increases stacking fault energies (SFEs) in Co-Cr alloys. Pt-modified Co-Cr alloys exhibited higher X-ray visibility than L605 and greater strength than Pt-Cr steel while maintaining comparable ductility. Collectively, these results indicate that carbon- and Pt-modified Co-Cr alloys are promising candidates for next-generation balloon-expandable stents, particularly thin-strut designs.

Zitieren

APA

Narushima, T., Friandani, S. S., Nakajima, T., Ueda, K., Sahara, R., & Alfirano, A. (2026). Carbon- and Platinum-Modified Co-Cr Alloys for Thin-Strut Stents. Journal of Biomimetics, Biomaterials and Biomedical Engineering, 72, 21-29. https://doi.org/10.4028/p-khm0g9

Vancouver

Narushima T, Friandani SS, Nakajima T, Ueda K, Sahara R, Alfirano A. Carbon- and Platinum-Modified Co-Cr Alloys for Thin-Strut Stents. Journal of Biomimetics, Biomaterials and Biomedical Engineering. 2026;72:21-29. doi:10.4028/p-khm0g9

BibTeX
@article{Narushima2026,
  author = {Narushima, Takayuki and Friandani, Sukma Suci and Nakajima, Tomoki and Ueda, Kyosuke and Sahara, Ryoji and Alfirano, Alfirano},
  title = {Carbon- and Platinum-Modified Co-Cr Alloys for Thin-Strut Stents},
  journal = {Journal of Biomimetics, Biomaterials and Biomedical Engineering},
  year = {2026},
  volume = {72},
  pages = {21--29},
  doi = {10.4028/p-khm0g9}
}
Kostenlos starten →