EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of PEEK and UHMWPE Cranial Implants Fabricated at Room Temperature Using Single Point Incremental Forming (SPIF)

Elizabeth Mamros, Austin Clark, Philip Barnett, Ihab Ragai, Shaffer Derek, Kristofer Laser Jr

Solid State Phenomena · 16.04.2026 · 389 · 37-49

DOI: 10.4028/p-cezq53 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Solid State Phenomena, online erschienen am 16.04.2026. Verfasst von Elizabeth Mamros und 5 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The human skull can become fractured or injured through impact and often requires repair through a craniectomy and subsequent cranioplasty, surgery performed to repair defects or damage to the cranium. Challenges related to material choice, which must be biocompatible, and customization for each patient’s anatomy remain. One possible solution is fabrication of patient-specific cranial implants, out of biocompatible polymers, using single point incremental forming (SPIF). In this paper, polyetheretherketone (PEEK) and ultra-high molecular weight polyethylene (UHMWPE) are formed using SPIF at room temperature to manufacture a cranial implant. The SPIF process is used to produce formed parts from which test specimens were extracted to evaluate the tensile performance and thermal properties. Formed cranial implants were impacted using a drop weight to evaluate their suitability under relevant conditions. The geometric conformance of the SPIF process was studied to compare the material behavior for the specified polymers after forming. The results validate that SPIF can be conducted at room temperature with PEEK and UHMWPE biocompatible polymers to enable custom implant manufacturing. However, PEEK exhibited superior performance in terms of tensile strength, geometric conformance, energy absorption, and melting temperature, and is recommended over UHMWPE for future implant applications.

Zitieren

APA

Mamros, E., Clark, A., Barnett, P., Ragai, I., Derek, S., & Jr, K. L. (2026). Comparison of PEEK and UHMWPE Cranial Implants Fabricated at Room Temperature Using Single Point Incremental Forming (SPIF). Solid State Phenomena, 389, 37-49. https://doi.org/10.4028/p-cezq53

Vancouver

Mamros E, Clark A, Barnett P, Ragai I, Derek S, Jr KL. Comparison of PEEK and UHMWPE Cranial Implants Fabricated at Room Temperature Using Single Point Incremental Forming (SPIF). Solid State Phenomena. 2026;389:37-49. doi:10.4028/p-cezq53

BibTeX
@article{Mamros2026,
  author = {Mamros, Elizabeth and Clark, Austin and Barnett, Philip and Ragai, Ihab and Derek, Shaffer and Jr, Kristofer Laser},
  title = {Comparison of PEEK and UHMWPE Cranial Implants Fabricated at Room Temperature Using Single Point Incremental Forming (SPIF)},
  journal = {Solid State Phenomena},
  year = {2026},
  volume = {389},
  pages = {37--49},
  doi = {10.4028/p-cezq53}
}
Kostenlos starten →