EUVIMEDEUVIMED entdecken
Crossref

CadCNN 1.0: A HYBRID DEEP NETWORK MODEL FOR CARDIAC ARRHYTHMIA DETECTION

Bipasha Patnaik, Santanu Sahoo, Debasish Swapnesh Kumar Nayak, Asit Kumar Subudhi

Biomedical Engineering: Applications, Basis and Communications · 2027-06 · 39 (04)

DOI: 10.4015/s1016237226500134 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Engineering: Applications, Basis and Communications, online erschienen am 22.05.2026. Verfasst von Bipasha Patnaik und 3 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiac Arrhythmia, which encompasses irregular heart rhythms such as tachycardia, bradycardia, ectopic pulses, represents a significant cause of cardiovascular morbidity and mortality worldwide, caused by disruptions in the heart’s electrical conduction system. Accurate and automated interpretation of the Electrocardiogram (ECG) is consequently crucial for the timely diagnosis and selection of treatment. This study introduces CadCNN 1.0, a novel hybrid Deep Learning (DL) framework that combines one-dimensional Convolutional Neural Networks (1D-CNN) for spatial feature extraction with Bidirectional Long Short-Term Memory (BiLSTM) for temporal sequence modeling. This methodology enables the accurate characterization of ECG waveforms and the model was trained and validated using the MIT-BIH Arrhythmia Database, classifying ECG signals into five categories: Normal (N), Fusion (F), Supraventricular Ectopic Beat (SVEB), Ventricular Ectopic Beat (VEB), and Unknown (Q) Beat. The Gray Wolf Optimization (GWO) algorithm was employed to optimize feature selection and model convergence, resulting in exceptional diagnostic performance with an Accuracy of 99.92%, Sensitivity (Recall) of 99.81%, Specificity of 99.93%, Precision of 99.92%, [Formula: see text]1-score of 99.92% along with MCC of 99.84% with Number of Wolves (Nw) of 10 represents the number of wolves in the population, corresponding to the number of candidate feature subsets simultaneously explored in each iteration, that enhances population diversity and prevents premature convergence and Max Iteration of 10 which denotes the maximum number of optimization cycles during which the wolves update their positions toward the optimal feature subset, ensuring iterative refinement, stability of global optimum. The confusion matrix demonstrates CadCNN 1.0’s discriminative ability to differentiate morphologically equivalent Arrhythmic classes with near-perfect precision, as evidenced by its strong diagonal dominance and minimal off-diagonal misclassifications. Furthermore, the Breast Cancer Dataset performed cross-domain validation, resulting in an Accuracy of 97.50%, Sensitivity (Recall) of 96.49%, Specificity of 97.18%, Precision of 96.49%, [Formula: see text]1-score of 96.49%, MCC of 92.53%. These results underscore the model’s adaptability to heterogeneous biomedical data. CadCNN 1.0 provides a clinically reliable, generalizable, computationally efficient computer-aided diagnostic system that advances automated Arrhythmia detection and enables intelligent, patient-centered healthcare diagnostics by integrating spatial-temporal feature learning, meta-heuristic optimization, and interpretable confusion-matrix validation.

Zitieren

APA

Patnaik, B., Sahoo, S., Nayak, D. S. K., & Subudhi, A. K. (2027). CadCNN 1.0: A HYBRID DEEP NETWORK MODEL FOR CARDIAC ARRHYTHMIA DETECTION. Biomedical Engineering: Applications, Basis and Communications, 39(04). https://doi.org/10.4015/s1016237226500134

Vancouver

Patnaik B, Sahoo S, Nayak DSK, Subudhi AK. CadCNN 1.0: A HYBRID DEEP NETWORK MODEL FOR CARDIAC ARRHYTHMIA DETECTION. Biomedical Engineering: Applications, Basis and Communications. 2027;39(04). doi:10.4015/s1016237226500134

BibTeX
@article{Patnaik2027,
  author = {Patnaik, Bipasha and Sahoo, Santanu and Nayak, Debasish Swapnesh Kumar and Subudhi, Asit Kumar},
  title = {CadCNN 1.0: A HYBRID DEEP NETWORK MODEL FOR CARDIAC ARRHYTHMIA DETECTION},
  journal = {Biomedical Engineering: Applications, Basis and Communications},
  year = {2027},
  volume = {39},
  number = {04},
  doi = {10.4015/s1016237226500134}
}
Kostenlos starten →