EUVIMEDEUVIMED entdecken
Crossref

Retentive force of a conical crown with CAD/CAM-fabricated PEEK and zirconia secondary crowns on titanium implant abutments

Abdullah Kamel, Toshiki Yamazaki, Natsuko Murakami, Huaxin Lyu, Kohei Komine, Amr Badr, Gehan Fekry, Hidekazu Takahashi, Noriyuki Wakabayashi

Dental Materials Journal · 2023

DOI: 10.4012/dmj.2022-188 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dental Materials Journal, 2023. Verfasst von Abdullah Kamel und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthetic Dentistry, Faculty of Dentistry, Minia University. Hauptthemen laut MEDLINE: Titanium, Crowns. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to evaluate the retentive force of polyetheretherketone (PEEK) and zirconia secondary crowns on ready-made titanium implant abutments (with height, diameter, and taper as 5.5 mm, 4.5 mm, and 6°, respectively) as the primary crown. PEEK, zirconia, and titanium secondary crowns were fabricated using a CAD/CAM system. Insertion and removal tests of secondary crowns on the primary crown were conducted for 2,000 cycles. The initial retentive forces recorded at the 100th cycle for PEEK, zirconia, and titanium were 13.0±7.9, 2.9±2.6, and 27.6±1.7 N, respectively. The retentive forces of PEEK and zirconia showed no significant difference among all cycles. However, the retentive force of the titanium used as a control decreased (20.3±2.8 N) significantly at the 2,000th cycle. Although the retentive force of PEEK was lower than that of titanium, it was within the range that can provide a suitable retentive force of 5 N for removable dental prostheses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumCrownsPolymersPolyethylene GlycolsKetonesZirconiumComputer-Aided DesignDental AbutmentsDental Stress AnalysisBenzophenones

Stichwörter der Autor:innen

CAD/CAMConical crownImplant overdentureRetentive force

Substanzen

TitaniumPolymersPolyethylene GlycolsKetonesZirconiumpolyetheretherketoneBenzophenoneszirconium oxide

Autor:innen und Institutionen

  • Department of Prosthetic Dentistry, Faculty of Dentistry, Minia University.
  • Advanced Prosthodontics, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University (TMDU).
  • Course of Oral Health Engineering, School of Oral Health Care Sciences, Faculty of Dentistry, Tokyo Medical and Dental University (TMDU).

Zitieren

APA

Kamel, A., Yamazaki, T., Murakami, N., Lyu, H., Komine, K., Badr, A., Fekry, G., Takahashi, H., & Wakabayashi, N. (2023). Retentive force of a conical crown with CAD/CAM-fabricated PEEK and zirconia secondary crowns on titanium implant abutments. Dental Materials Journal. https://doi.org/10.4012/dmj.2022-188

Vancouver

Kamel A, Yamazaki T, Murakami N, Lyu H, Komine K, Badr A, et al. Retentive force of a conical crown with CAD/CAM-fabricated PEEK and zirconia secondary crowns on titanium implant abutments. Dental Materials Journal. 2023. doi:10.4012/dmj.2022-188

BibTeX
@article{Kamel2023,
  author = {Kamel, Abdullah and Yamazaki, Toshiki and Murakami, Natsuko and Lyu, Huaxin and Komine, Kohei and Badr, Amr and Fekry, Gehan and Takahashi, Hidekazu and Wakabayashi, Noriyuki},
  title = {Retentive force of a conical crown with CAD/CAM-fabricated PEEK and zirconia secondary crowns on titanium implant abutments},
  journal = {Dental Materials Journal},
  year = {2023},
  doi = {10.4012/dmj.2022-188}
}
Kostenlos starten →