EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Segmentation of the Hyperdense Artery Sign on Noncontrast CT in Ischemic Stroke Using Artificial Intelligence

Pyeong Eun Kim iD, Sue Young Ha iD, Myungjae Lee iD, Nakhoon Kim iD, Wi-Sun Ryu iD, Leonard Sunwoo iD, Beom Joon Kim iD

Journal of Clinical Neurology · 2025 · 21 (4) · 305

DOI: 10.3988/jcn.2024.0560 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Neurology, 2025. Verfasst von Pyeong Eun Kim und 6 weiteren Autor:innen. Beteiligte Einrichtung: Artificial Intelligence Research Center, JLK Inc., Seoul, Korea. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Multiministry Grant for Medical Device Development, Korea Health Industry Development Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND PURPOSE: We developed and validated an automated hyperdense artery sign (HAS) segmentation algorithm for the distal internal carotid artery and middle cerebral artery on noncontrast brain computed tomography (NCCT) using a multicenter dataset with independent annotation performed by two experts. METHODS: For training and external validation, we included patients with ischemic stroke who underwent concurrent NCCT and CT angiography between May 2011 and December 2022 at six hospitals and one hospital, respectively. For clinical validation, nonoverlapping patients admitted within 24 hours of onset were consecutively included between December 2020 and April 2023 from six hospitals. The model was trained using the 2D U-Net deep-learning architecture with manual annotation by two experts. We constructed models trained on datasets annotated individually by each expert, and an ensemble model using shuffled annotations by both experts. The performance of the models was compared using the area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity. RESULTS: This study included 673, 365, and 774 patients in the training/internal validation, external validation, and clinical validation datasets, respectively, who were aged 68.8±13.2, 67.8±13.4, and 68.8±13.6 years (mean±standard deviation) and comprised 55.0%, 59.5%, and 57.6% males. The ensemble model achieved higher AUROC and sensitivity than the models trained on annotations by a single expert in the external validation. For the clinical validation dataset, the ensemble model exhibited an AUROC of 0.846 (95% confidence interval [CI], 0.819-0.871), sensitivity of 76.8% (95% CI, 65.1%-86.1%), and specificity of 88.5% (95% CI, 85.9%-90.8%). The predicted volume of the clot was correlated with the infarct volume in follow-up diffusion-weighted imaging (r=0.42, p

Schlagwörter

Stichwörter der Autor:innen

computed tomographydeep learninghyperdense artery signischemic stroke

Autor:innen und Institutionen

  • Artificial Intelligence Research Center, JLK Inc., Seoul, Korea.
  • Department of Neurology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.
  • Artificial Intelligence Research Center, JLK Inc., Seoul, Korea. wisunryu@gmail.com.
  • Department of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea. leonard.sunwoo@gmail.com.

ORCID-Profile: Pyeong Eun Kim, Sue Young Ha, Myungjae Lee, Nakhoon Kim, Wi-Sun Ryu, Leonard Sunwoo, Beom Joon Kim

Förderung

  • Multiministry Grant for Medical Device Development
  • Korea Health Industry Development Institute

Zitieren

APA

Kim, P. E., Ha, S. Y., Lee, M., Kim, N., Ryu, W. S., Sunwoo, L., & Kim, B. J. (2025). Segmentation of the Hyperdense Artery Sign on Noncontrast CT in Ischemic Stroke Using Artificial Intelligence. Journal of Clinical Neurology, 21(4), 305. https://doi.org/10.3988/jcn.2024.0560

Vancouver

Kim PE, Ha SY, Lee M, Kim N, Ryu WS, Sunwoo L, et al. Segmentation of the Hyperdense Artery Sign on Noncontrast CT in Ischemic Stroke Using Artificial Intelligence. Journal of Clinical Neurology. 2025;21(4):305. doi:10.3988/jcn.2024.0560

BibTeX
@article{Kim2025,
  author = {Kim, Pyeong Eun and Ha, Sue Young and Lee, Myungjae and Kim, Nakhoon and Ryu, Wi-Sun and Sunwoo, Leonard and Kim, Beom Joon},
  title = {Segmentation of the Hyperdense Artery Sign on Noncontrast CT in Ischemic Stroke Using Artificial Intelligence},
  journal = {Journal of Clinical Neurology},
  year = {2025},
  volume = {21},
  number = {4},
  pages = {305},
  doi = {10.3988/jcn.2024.0560}
}
Kostenlos starten →