Kinetics of the amino acid uptake tracer O-(2-[$^{18}$F]fluoroethyl)-L-tyrosine (FET) in human brain
Repository for Publications and Research Data (ETH Zurich) · 01.01.2025
DOI: 10.3929/ethz-b-000748870 ↗Kurz gefasst
Fachartikel in der Zeitschrift Repository for Publications and Research Data (ETH Zurich), erschienen am 01.01.2025. Verfasst von Korbinian Krieger und 8 weiteren Autor:innen.
Abstract (Originalsprache)
Background
The large neutral amino acid [$^{18}$F]fluoroethoxy-L-tyrosine ([$^{18}$F]FET) is a popular tracer for detection and staging of intracranial tumors by positron emission tomography (PET). While its high tumoral uptake reflects over-expression of the L-type amino acid transporter (LAT1), there is little knowledge about the kinetics of [$^{18}$F]FET uptake in healthy brain tissue, owing to the limited PET data in healthy volunteers, and to the requirement of an arterial input function for compartmental analysis. To address this, we used long axial field-of-view (LAFOV) dynamic 40-min recordings of 28 post-operative patients with intracranial tumors to undertake parametric brain mapping relative to an image-derived arterial input function (IDIF) obtained from the aorta. We averaged the individual parametric maps to obtain estimates of the physiological uptake relatively unaffected by individual residual lesions and resections, and tested simplified single-frame methods for quantitation.
Results
The analyses yielded estimates of regional unidirectional blood–brain clearance K$_1$ (0.00825–0.0244 ml g$^{−1}$ min$^{−1}$), net blood–brain clearance K$_{in}$ (0.00448–0.00913 ml g$^{−1}$ min$^{−1}$), and equilibrium distribution volume V$_T$ (0.126–0.495 ml g$^{−1}$), where the lowest values depict white matter, and the highest values cerebellum. In our test of a simplified quantitation of [$^{18}$F]FET uptake from single frame recordings, i.e., Gjedde–Patlak multilinear graphic analyses of K$_1$ at five min post-injection and K$_{in}$ at 40 min post injection, results were in good agreement with the analyses from the dynamic recordings (< 10% error).
Conclusions
Compartmental analysis results for [$^{18}$F]FET uptake in extra-tumoral human brain regions are in accord with the few prior reports, mainly obtained in experimental animals, and support the use of single frame quantitation. Present findings in relatively healthy brain should inform the interpretation of pathological [$^{18}$F]FET uptake in tumors.
Schlagwörter
Zitieren
APA
Krieger, K., Pyka, Thomas, Mingels, C., Sari, H., GJEDDE, A. H., Rominger, Axel, & Cumming, P. D. (2025). Kinetics of the amino acid uptake tracer O-(2-[$^{18}$F]fluoroethyl)-L-tyrosine (FET) in human brain. Repository for Publications and Research Data (ETH Zurich). https://doi.org/10.3929/ethz-b-000748870
Vancouver
Krieger K, Pyka, Thomas, Mingels C, Sari H, GJEDDE AH, et al. Kinetics of the amino acid uptake tracer O-(2-[$^{18}$F]fluoroethyl)-L-tyrosine (FET) in human brain. Repository for Publications and Research Data (ETH Zurich). 2025. doi:10.3929/ethz-b-000748870
BibTeX
@article{Krieger2025,
author = {Krieger, Korbinian and Pyka and Thomas and Mingels, Clemens and Sari, Hasan and GJEDDE, ALBERT H. and Rominger and Axel and Cumming, Paul D.},
title = {Kinetics of the amino acid uptake tracer O-(2-[$^18$F]fluoroethyl)-L-tyrosine (FET) in human brain},
journal = {Repository for Publications and Research Data (ETH Zurich)},
year = {2025},
doi = {10.3929/ethz-b-000748870}
}
EUVIMED