Klinisches Management von Patienten mit Kavernomen des zentralen Nervensystems: Ein Update und Empfehlungen für die klinische Praxis

Torben P.P. Hornung, Néha Koonjoo, Sheng Shen, Friderike K. Longarino, Kathryn E. Keenan, Susu Yan, Thomas R Bortfeld, Matthew Scott Rosen

Repository for Publications and Research Data (ETH Zurich) · 01.05.2025

DOI: 10.3929/ethz-b-000734068 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Repository for Publications and Research Data (ETH Zurich), erschienen am 01.05.2025. Verfasst von Torben P.P. Hornung und 7 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Ultra-low field (ULF) magnetic resonance imaging of the breast and chest wall was conducted using optimized radiofrequency (RF) coil designs, and to explore future applications in MR-guided proton therapy (MRgPT), simulation studies of a pencil proton beam trajectory in low and ULFs were conducted.

Methods

The focus in this study is the RF coil design, which is approached as a multi-objective optimization (MOO) problem and solved using a defined performance metric and Pareto optimality formalism. Our winding pattern algorithm was developed to simultaneously optimize the coil's magnetic field homogeneity, signal-to-noise ratio (SNR), and magnetic field drop-off into the chest wall for improved imaging of organs-at-risk. Five single-channel, transmit/receive breast-shaped RF coils were constructed. 3D phantom MRI was performed at 6.5 mT to evaluate field homogeneity and SNR. The first in vivo breast imaging at 6.5 mT was conducted. Monte Carlo simulations were employed to investigate the effects of copper wire and static field strengths on proton beam deflection.

Results

The MOO method was validated - the observed field homogeneity, the relative ratio of SNRs, and the MRI chest signal agreed for all coils with the simulations. In vivo imaging revealed good breast tissue contrast and clear heart visualization. Our findings indicated that a similar to 50 mT field with similar to 10 mT/m gradient strengths can minimize proton beam deflection, achieving similar to 2 x 2 x 5 mm(3) spatial resolution within minutes, supporting the clinical feasibility of MRgPT.

Conclusion

Our MOO method can be used to design breast coils that meet a wide range of imaging requirements..

Schlagwörter

clinical managementultra-low-field MRIbreast MRIRF coil designmulti-objective optimizationchest wall imagingmagnetic field homogeneity

Zitieren

APA

Hornung, T. P., Koonjoo, N., Shen, S., Longarino, F. K., Keenan, K. E., Yan, S., Bortfeld, T. R., & Rosen, M. S. (2025). Klinisches Management von Patienten mit Kavernomen des zentralen Nervensystems: Ein Update und Empfehlungen für die klinische Praxis. Repository for Publications and Research Data (ETH Zurich). https://doi.org/10.3929/ethz-b-000734068

Vancouver

Hornung TP, Koonjoo N, Shen S, Longarino FK, Keenan KE, Yan S, et al. Klinisches Management von Patienten mit Kavernomen des zentralen Nervensystems: Ein Update und Empfehlungen für die klinische Praxis. Repository for Publications and Research Data (ETH Zurich). 2025. doi:10.3929/ethz-b-000734068

BibTeX
@article{Hornung2025,
  author = {Hornung, Torben P.P. and Koonjoo, Néha and Shen, Sheng and Longarino, Friderike K. and Keenan, Kathryn E. and Yan, Susu and Bortfeld, Thomas R and Rosen, Matthew Scott},
  title = {Klinisches Management von Patienten mit Kavernomen des zentralen Nervensystems: Ein Update und Empfehlungen für die klinische Praxis},
  journal = {Repository for Publications and Research Data (ETH Zurich)},
  year = {2025},
  doi = {10.3929/ethz-b-000734068}
}
Kostenlos starten →