EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of diagnostic efficacy of galactomannan lateral flow assay vs enzyme immunoassay: importance of storage conditions

Enes Erbağcı, Ayşe Ö Mete, Handan H Şahin, Yasemin Zer, İlkay Karaoğlan

The Journal of Infection in Developing Countries · 2025

DOI: 10.3855/jidc.20587 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Infection in Developing Countries, 2025. Verfasst von Enes Erbağcı und 4 weiteren Autor:innen. Beteiligte Einrichtung: Ağrı Training and Research Hospital, İnfectious Diseases, Ağrı, Turkey. Hauptthemen laut MEDLINE: Mannans, Specimen Handling, Aspergillosis, Antigens, Fungal. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Gaziantep Üniversitesi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Galactomannan antigen is a valuable biomarker for diagnosing invasive aspergillosis. Traditional methods, such as enzyme immunoassays (EIA), require batch sampling, whereas lateral flow assays (LFA) provide a simpler and faster diagnostic process. This study aimed to compare the diagnostic efficacy of both testing methods. Methodology: This prospective case-control study involved 192 serum samples categorized according to the European Organization for Research and Treatment of Cancer/Mycoses Study Group (EORTC/MSG criteria). LFA were conducted following the manufacturer’s instructions, utilizing a cube reader. Receiver operating characteristic (ROC) analysis was performed to determine the optimal LFA threshold, and concordance analysis was conducted for both assays.

Results

The indicated sensitivity and specificity of LFA at the recommended galactomannan index threshold (GMI ≥ 0.5) were 15.3% (9/59) and 99% (132/133), respectively. Post-ROC analysis at a threshold of 0.4 revealed an area under the curve (AUC) of 0.685, with sensitivity, specificity, positive predictive value, and negative predictive value at 18%, 99%, 91%, and 73%, respectively. Qualitative agreement between the tests, assessed using the Kappa statistic, indicated a very low degree of agreement (κ = 0.18). In contrast, quantitative agreement, evaluated through Kendall’s W-test, demonstrated a very high degree of agreement (W = 0.84).

Conclusions

Despite previous literature suggesting the efficacy of LFA, our study found it unsuitable for screening due to its low sensitivity. We recommend exercising caution regarding the manufacturer's storage recommendations until further studies on sample storage conditions are conducted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MannansSpecimen HandlingAspergillosisAntigens, FungalHumansGalactoseSensitivity and SpecificityProspective StudiesCase-Control StudiesMaleFemaleMiddle AgedAdultImmunoenzyme TechniquesROC CurveAgedYoung AdultPredictive Value of TestsBiomarkers

Stichwörter der Autor:innen

Aspergillusaspergillosisdiagnosisgalactomannanserum

Substanzen

galactomannanGalactoseMannansAntigens, FungalBiomarkers

Autor:innen und Institutionen

  • Ağrı Training and Research Hospital, İnfectious Diseases, Ağrı, Turkey.
  • Gaziantep University Faculty of Medicine, İnfectious Diseases, Gaziantep, Turkey.
  • Liv Hospital Gaziantep, Hematology, Gaziantep, Turkey.
  • Gaziantep University Faculty of Medicine, Medical Microbiology, Gaziantep, Turkey.

Förderung

  • Gaziantep Üniversitesi

Zitieren

APA

Erbağcı, E., Mete, A. Ö., Şahin, H. H., Zer, Y., & Karaoğlan, İ. (2025). Comparison of diagnostic efficacy of galactomannan lateral flow assay vs enzyme immunoassay: importance of storage conditions. The Journal of Infection in Developing Countries. https://doi.org/10.3855/jidc.20587

Vancouver

Erbağcı E, Mete AÖ, Şahin HH, Zer Y, Karaoğlan İ. Comparison of diagnostic efficacy of galactomannan lateral flow assay vs enzyme immunoassay: importance of storage conditions. The Journal of Infection in Developing Countries. 2025. doi:10.3855/jidc.20587

BibTeX
@article{Erbac2025,
  author = {Erbağcı, Enes and Mete, Ayşe Ö and Şahin, Handan H and Zer, Yasemin and Karaoğlan, İlkay},
  title = {Comparison of diagnostic efficacy of galactomannan lateral flow assay vs enzyme immunoassay: importance of storage conditions},
  journal = {The Journal of Infection in Developing Countries},
  year = {2025},
  doi = {10.3855/jidc.20587}
}
Kostenlos starten →