Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Infection in Developing Countries, 2024. Verfasst von Demet Hacıseyitoğlu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Microbiology, Medical Faculty, Maltepe University, Istanbul, Türkiye. Hauptthemen laut MEDLINE: SARS-CoV-2, Antibodies, Viral, COVID-19, Immunoglobulin G. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

We investigated the effect of two preanalytical variables, temperature change and freezing-thawing of serum samples, on severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgG levels. Methodology: Serum samples were collected from patients who had coronavirus disease 2019 (COVID-19) prior to vaccination. Six serum samples were included, two each with high positivity (HP), low positivity (LP), and a level of close-to-detection limit (CDL) for SARS-CoV-2 IgG. Each of these six samples was divided into three tubes and placed in refrigerators at 4-8 °C, -20 °C, and -70 °C; removed from the storage temperature once per day for 20 consecutive days; and assayed for SARS-CoV-2 IgG level.

Results

The coefficient of variation of all the remaining serum samples were within 95% except for CDL-1 serum at -70 °C, HP-2 serum at 4-8 °C, HP-2 serum at -20 °C, and HP-2 serum at -70 °C. The levels increased significantly when the temperature in the samples with CDL was reduced. The values in samples with LP at -20 °C and -70 °C were significantly higher than those at 4-8°C. In the case of samples with HP, the values of samples at -20 °C were higher than those in samples at 4-8 °C. There was no positive–negative change during any of the freeze-thaw cycles.

Conclusions

Antibody value in the samples at 4-8 °C remained stable throughout the 20 freeze-thaw cycles. The antibody value of the samples at -20 °C and -70 °C tended to elevate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SARS-CoV-2Antibodies, ViralCOVID-19Immunoglobulin GSpecimen HandlingHumansTemperatureFreezing

Stichwörter der Autor:innen

SARS-CoV-2 IgGfreeze-thawserumstability

Substanzen

Antibodies, ViralImmunoglobulin G

Autor:innen und Institutionen

  • Department of Microbiology, Medical Faculty, Maltepe University, Istanbul, Türkiye.
  • Department of Microbiology, Medical Faculty, Karabuk University, Karabuk, Türkiye.
  • Department of Microbiology, Medical Faculty, Bulent Ecevit University, Zonguldak, Türkiye.

Zitieren

APA

Hacıseyitoğlu, D., Yılmaz, Ş., Erdoğan, F., & Cömert, F. (2024). Stability of SARS-CoV-2 antibody in serum under various usage and storage conditions. The Journal of Infection in Developing Countries. https://doi.org/10.3855/jidc.18919

Vancouver

Hacıseyitoğlu D, Yılmaz Ş, Erdoğan F, Cömert F. Stability of SARS-CoV-2 antibody in serum under various usage and storage conditions. The Journal of Infection in Developing Countries. 2024. doi:10.3855/jidc.18919

BibTeX
@article{Hacseyitolu2024,
  author = {Hacıseyitoğlu, Demet and Yılmaz, Şerife and Erdoğan, Fatma and Cömert, Füsun},
  title = {Stability of SARS-CoV-2 antibody in serum under various usage and storage conditions},
  journal = {The Journal of Infection in Developing Countries},
  year = {2024},
  doi = {10.3855/jidc.18919}
}
Kostenlos starten →