EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY-NC-ND 4.0

Sensitive electrochemical sensor of levofloxacin using boron-doped diamond (BDD) electrode modified with Ti3C2TX (MXene) material

Prastika Krisma Jiwanti, Indah Harindy Putri, Grandprix T M Kadja, Yasuaki Einaga, Laurencia Gabrielle Sutanto, Siti Wafiroh, Dewi Kartika Azizah Sukardi, Anis Puspita Sari, Tahta Amrillah, Ilma Amalina, Qonita Kurnia Anjani, Wan Jeffrey Basirun

Journal of Food and Drug Analysis · 13.09.2024 · 32 (3) · 348-357

DOI: 10.38212/2224-6614.3517 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Food and Drug Analysis, online erschienen am 13.09.2024. Verfasst von Prastika Krisma Jiwanti und 11 weiteren Autor:innen. Beteiligte Einrichtung: Nanotechnology Engineering, Faculty of Advanced Technology and Multidiscipline, Universitas Airlangga, Surabaya 60115, Indonesia. Hauptthemen laut MEDLINE: Levofloxacin, Boron, Diamond, Electrodes. Die Arbeit wurde bisher 11-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Overuse of levofloxacin (LEV) is often associated with bacterial resistance and serious health problems, underscoring the need for reliable sensing and monitoring of LEV molecules. Therefore, this study aimed to investigate LEV using boron-doped diamond (BDD) and boron-doped diamond modified with MXene (Ti3C2TX) (BDD-MXene) electrode. The successful deposition of MXene on the BDD surface was confirmed using scanning electron microscope (SEM). Cyclic voltammetry (CV) and square wave voltammetry (SWV) methods were also applied to evaluate the electrochemical behavior. The results showed that both electrodes had a linear response in the range of 30-100 µM. The limit of detection (LOD) and limit of quantitation (LOQ) were found to be 1.0 x 10-6 M and 3.37 x 10-6 M for bare-BDD, while on BDD-MXene, the values were 3.90 x 10-7 M and 1.30 x 10-6 M, respectively. Furthermore, both electrodes showed good responses on selectivity tests with glucose and another fluoroquinolone antibiotic such as ciprofloxacin. The results also indicated good precision with %RSD less than 5%. In real sample applications using wastewater, bare-BDD and BDD-MXene produced excellent %recovery of 92.96% and 101.29%, respectively.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LevofloxacinBoronDiamondElectrodesElectrochemical TechniquesTitaniumAnti-Bacterial AgentsLimit of DetectionBiosensing Techniques

Substanzen

LevofloxacinBoronDiamondTitaniumAnti-Bacterial Agents

Autor:innen und Institutionen

  • Nanotechnology Engineering, Faculty of Advanced Technology and Multidiscipline, Universitas Airlangga, Surabaya 60115, Indonesia.
  • Airlangga Functional Nanomaterials Research Group, Faculty of Advanced Technology and Multidiscipline, Universitas Airlangga, Surabaya 60115, Indonesia.
  • Department of Chemistry, Faculty of Science and Technology, Universitas Airlangga, Surabaya, 60115, Indonesia.
  • Division of Inorganic and Physical Chemistry, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesha No. 10, Bandung 40132, Indonesia.
  • Center for Catalysis and Reaction Engineering, Institut Teknologi Bandung, Jl. Ganesha No. 10, Bandung 40132, Indonesia.
  • Research Center for Nanosciences and Nanotechnology, Institut Teknologi Bandung, Jl. Ganesha No. 10, Bandung 40132, Indonesia.

Zitieren

APA

Jiwanti, P. K., Putri, I. H., Kadja, G. T. M., Einaga, Y., Sutanto, L. G., Wafiroh, S., Sukardi, D. K. A., Sari, A. P., Amrillah, T., Amalina, I., Anjani, Q. K., & Basirun, W. J. (2024). Sensitive electrochemical sensor of levofloxacin using boron-doped diamond (BDD) electrode modified with Ti3C2TX (MXene) material. Journal of Food and Drug Analysis, 32(3), 348-357. https://doi.org/10.38212/2224-6614.3517

Vancouver

Jiwanti PK, Putri IH, Kadja GTM, Einaga Y, Sutanto LG, Wafiroh S, et al. Sensitive electrochemical sensor of levofloxacin using boron-doped diamond (BDD) electrode modified with Ti3C2TX (MXene) material. Journal of Food and Drug Analysis. 2024;32(3):348-357. doi:10.38212/2224-6614.3517

BibTeX
@article{Jiwanti2024,
  author = {Jiwanti, Prastika Krisma and Putri, Indah Harindy and Kadja, Grandprix T M and Einaga, Yasuaki and Sutanto, Laurencia Gabrielle and Wafiroh, Siti and Sukardi, Dewi Kartika Azizah and Sari, Anis Puspita and Amrillah, Tahta and Amalina, Ilma and Anjani, Qonita Kurnia and Basirun, Wan Jeffrey},
  title = {Sensitive electrochemical sensor of levofloxacin using boron-doped diamond (BDD) electrode modified with Ti3C2TX (MXene) material},
  journal = {Journal of Food and Drug Analysis},
  year = {2024},
  volume = {32},
  number = {3},
  pages = {348--357},
  doi = {10.38212/2224-6614.3517}
}
Kostenlos starten →