Introduction
Buccal shelf area (BSA) is a recommended anatomic site for mini-screw insertion. Stability of miniscrew is determined by quantity of bone available in the region.
Objective
To determine bone thickness and height of BSA for optimum placement of miniscrew. Materials and Methods: This cross-sectional observational study included 40 cone-beam computed tomography (CBCT) scans (23 males, 17 females) of patients aged 19-38 years. Patients were further divided into two age groups 19-28 years and 29-38 years. Measurements were made at 4 different sites: mandibular first molar mesial root (M6) and distal root (D6), second molar mesial root (M7) and distal root (D7). Bone thicknesses were measured at 6 mm and 11 mm apical to the cementoenamel junction (CEJ), and bone heights at 4 mm and 5 mm buccal to the CEJ. Analysis of variance was used to compare bone thickness and height at different sites. Independent t-Test compared the difference in bone thickness and height between gender and age groups.
Results
Bone thickness significantly increased from M6 to D7 at both 6 mm and 11 mm levels (PP Conclusion: The optimal sites for miniscrew placement in buccal shelf area are distal root of second molar at 6 mm, and mesial and distal roots of second molar at 11 mm apical to CEJ.
Zitieren
APA
Shrestha, R., Shrestha, R. M., Dhakal, J., & Shrestha, S. (2026). Evaluation of Mandibular Buccal Shelf Bone Thickness and Height for Miniscrew Placement Using Cone-Beam Computed Tomography. Taiwanese Journal of Orthodontics, 37(4). https://doi.org/10.38209/2708-2636.1387
Vancouver
Shrestha R, Shrestha RM, Dhakal J, Shrestha S. Evaluation of Mandibular Buccal Shelf Bone Thickness and Height for Miniscrew Placement Using Cone-Beam Computed Tomography. Taiwanese Journal of Orthodontics. 2026;37(4). doi:10.38209/2708-2636.1387
BibTeX
@article{Shrestha2026,
author = {Shrestha, Roji and Shrestha, Rabindra Man and Dhakal, Jyoti and Shrestha, Sujita},
title = {Evaluation of Mandibular Buccal Shelf Bone Thickness and Height for Miniscrew Placement Using Cone-Beam Computed Tomography},
journal = {Taiwanese Journal of Orthodontics},
year = {2026},
volume = {37},
number = {4},
doi = {10.38209/2708-2636.1387}
}
EUVIMED