EUVIMEDEUVIMED entdecken
Crossref

Stand-Alone PR Controlled Three-Phase Four-Leg Voltage Source Inverter with Linear and Non-Linear Loads

Kiran Reddy Masarla

International Journal of Innovative Science and Research Technology · 01.05.2026 · 2723

DOI: 10.38124/ijisrt/26apr633 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Innovative Science and Research Technology, online erschienen am 01.05.2026. Verfasst von Kiran Reddy Masarla. Die Arbeit nennt 20 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents a comprehensive simulation study of a stand-alone three-phase four-leg voltage source inverter (VSI) operating under both linear and non-linear load conditions. The conventional split-capacitor three-phase three-leg inverter topology suffers from inherent voltage imbalance issues and requires bulky capacitor banks, whereas the four-leg topology eliminates these drawbacks by providing an independent neutral current path. Two control strategies are investigated: the proportional-resonant (PR) controller and the proportional (P) controller, both implemented within a dual-loop voltage and current regulation framework. The space vector pulse width modulation (SVPWM) technique, realized via an offset voltage injection approach, is adopted as the switching modulation scheme. Simulation results are presented and analyzed for balanced resistive (R) loads, unbalanced R loads, balanced and unbalanced resistive-inductive (RL) loads, and non-linear diode-rectifier loads. Performance indices including total harmonic distortion (THD), RMS load current, and neutral current magnitude are evaluated and compared across all loading scenarios.

Zitieren

APA

Masarla, K. R. (2026). Stand-Alone PR Controlled Three-Phase Four-Leg Voltage Source Inverter with Linear and Non-Linear Loads. International Journal of Innovative Science and Research Technology, 2723. https://doi.org/10.38124/ijisrt/26apr633

Vancouver

Masarla KR. Stand-Alone PR Controlled Three-Phase Four-Leg Voltage Source Inverter with Linear and Non-Linear Loads. International Journal of Innovative Science and Research Technology. 2026:2723. doi:10.38124/ijisrt/26apr633

BibTeX
@article{Masarla2026,
  author = {Masarla, Kiran Reddy},
  title = {Stand-Alone PR Controlled Three-Phase Four-Leg Voltage Source Inverter with Linear and Non-Linear Loads},
  journal = {International Journal of Innovative Science and Research Technology},
  year = {2026},
  pages = {2723},
  doi = {10.38124/ijisrt/26apr633}
}
Kostenlos starten →