EUVIMEDEUVIMED entdecken
Crossref

Evaluation of the accuracy of working length determination and automatic apical reverse function accuracy of endodontic rotary motor integrated apex locator: an in-vitrostudy

Nanda Kishore K, Madhu Varma K, Girija S Sajjan, Kalyan Satish R, Raheem Md, Anitha Viswanadhan

International Journal of Dental Materials · 2020

DOI: 10.37983/ijdm.2020.2101 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Dental Materials, 2020. Verfasst von Nanda Kishore K und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The outcome of a Root canal therapy depends upon complete cleaning of the root canal system without damaging periapical integrity.Accurate determination of working length determination is essential.The development of Endodontic motor integrated apex locators (EALs) for locating canal terminus has been significant innovation in the field of Endodontics.

Aim

To evaluate the accuracy of Endomotor integrated electronic apex locator in determining the working length before and after cleaning and shaping with Automatic Apical Reverse action set at the "0.5mm" mark.Materials and methods: Forty extracted premolars were decoronated, patency was verified.The actual length of tooth measured and teeth were embedded in alginate and file was advanced.Readings at the apex and 0.5mm short of the apex was recorded using Dentaport ZX (DZ group) and EConnect S (ES group) apex locator.Cleaning and shaping were done with rotary files with Automatic Apical Reverse action set at 0.5mm short of apex and reading recorded as Automatic Apical Reverse Length (AARL), and actual tooth length is measured.The data obtained were statistically analyzed.

Results

Within the limitations of the study, the EALs readings of the DZ group & ES group provided an acceptable determination of working length within range ± 0.5mm, and AAR function set at 0.5mm mark of Endomotor integrated apex locator (E Connect S) provided an adequate apical limit.

Conclusion

Under the in vitro conditions of this study, both Electronic Apex Locators showed an acceptable determination of working length within range ± 0.5mm from the actual length.The AAR function set at the 0.5mm mark of Econnect S provided an adequate apical limit.

Zitieren

APA

K, N. K., K, M. V., Sajjan, G. S., R, K. S., Md, R., & Viswanadhan, A. (2020). Evaluation of the accuracy of working length determination and automatic apical reverse function accuracy of endodontic rotary motor integrated apex locator: an in-vitrostudy. International Journal of Dental Materials. https://doi.org/10.37983/ijdm.2020.2101

Vancouver

K NK, K MV, Sajjan GS, R KS, Md R, Viswanadhan A. Evaluation of the accuracy of working length determination and automatic apical reverse function accuracy of endodontic rotary motor integrated apex locator: an in-vitrostudy. International Journal of Dental Materials. 2020. doi:10.37983/ijdm.2020.2101

BibTeX
@article{K2020,
  author = {K, Nanda Kishore and K, Madhu Varma and Sajjan, Girija S and R, Kalyan Satish and Md, Raheem and Viswanadhan, Anitha},
  title = {Evaluation of the accuracy of working length determination and automatic apical reverse function accuracy of endodontic rotary motor integrated apex locator: an in-vitrostudy},
  journal = {International Journal of Dental Materials},
  year = {2020},
  doi = {10.37983/ijdm.2020.2101}
}
Kostenlos starten →