EUVIMEDEUVIMED entdecken
Video/Audio

A Paper-Based Electrochemiluminescence Lateral Flow Immunoassay Using Ruthenium Complex Labeling for the Detection of Naja Naja Venom

Yicai Gan, Shichao Yuan, Wei Chen, Hongbin Zhang, Bo Xu

Journal of Visualized Experiments · 05.11.2026 · (237)

DOI: 10.3791/74022 ↗

Kurz gefasst

Video/Audio in der Zeitschrift Journal of Visualized Experiments, online erschienen am 05.11.2026. Verfasst von Yicai Gan und 4 weiteren Autor:innen. Beteiligte Einrichtung: The First School of Clinical Medicine, Southern Medical University. Hauptthemen laut MEDLINE: Elapid Venoms, Luminescent Measurements, Ruthenium, Electrochemical Techniques.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An indirect competitive paper-based electrochemiluminescence (ECL) lateral flow immunoassay was developed for quantitative detection of Naja naja venom. Equine anti-Naja naja venom IgG served as the primary recognition antibody, ruthenium-complex-labeled rabbit anti-equine IgG as the ECL reporter and immobilized three-finger toxin (3FTX) as the competitive antigen. Ruthenium labeling conditions, the co-reactant system, detection membrane, membrane length, and the labeled-secondary-antibody-to-3FTX ratio were optimized. The selected conditions were a Ru-NHS (ruthenium-complex N-hydroxysuccinimide) ester-to-secondary-antibody molar ratio of 160:1 at 25 °C, Elecsys buffer as the co-reactant, Whatman AE 100 as a 1.5 cm detection membrane, and a 3000:1 secondary-antibody-to-3FTX concentration ratio. The whole-venom calibration series was fitted with a decreasing four-parameter logistic model (R2 = 0.9980). Blank-threshold analysis followed by six-run low-concentration verification supported a practical limit of detection of 32 ng/mL. Quantitative verification identified a limit of quantitation (LOQ) of 300 ng/mL and a validated quantitative range of 300-10,000 ng/mL. The within-batch coefficient of variation (CV) was 3.46%, and the coefficient of variation among three batch means was 1.63%. At 10,000 ng/mL, Naja naja venom produced a lower ECL response than Deinagkistrodon acutus venom, Bungarus multicinctus venom, serum, and phosphate-buffered saline controls. These findings support the analytical feasibility of the competitive paper-based ECL platform and provide a basis for further matrix, cross-reactivity, stability, and clinical-sample validation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elapid VenomsLuminescent MeasurementsRutheniumElectrochemical TechniquesAnimalsImmunoassayPaperNaja najaImmunoglobulin G

Substanzen

Elapid VenomsRutheniumImmunoglobulin G

Autor:innen und Institutionen

  • The First School of Clinical Medicine, Southern Medical University.
  • Laboratory of Basic Medical Sciences, General Hospital of Southern Theater Command of PLA.
  • Department of Anesthesiology, General Hospital of Southern Theater Command of PLA.
  • Department of Anesthesiology, General Hospital of Southern Theater Command of PLA; xubo333@hotmail.com.

Zitieren

APA

Gan, Y., Yuan, S., Chen, W., Zhang, H., & Xu, B. (2026). A Paper-Based Electrochemiluminescence Lateral Flow Immunoassay Using Ruthenium Complex Labeling for the Detection of Naja Naja Venom. Journal of Visualized Experiments. https://doi.org/10.3791/74022

Vancouver

Gan Y, Yuan S, Chen W, Zhang H, Xu B. A Paper-Based Electrochemiluminescence Lateral Flow Immunoassay Using Ruthenium Complex Labeling for the Detection of Naja Naja Venom. Journal of Visualized Experiments. 2026. doi:10.3791/74022

BibTeX
@article{Gan2026,
  author = {Gan, Yicai and Yuan, Shichao and Chen, Wei and Zhang, Hongbin and Xu, Bo},
  title = {A Paper-Based Electrochemiluminescence Lateral Flow Immunoassay Using Ruthenium Complex Labeling for the Detection of Naja Naja Venom},
  journal = {Journal of Visualized Experiments},
  year = {2026},
  number = {237},
  doi = {10.3791/74022}
}