Background

The rehabilitation of the severely atrophic maxilla with zygomatic implants (ZIs) presents unique surgical challenges. While various techniques exist, there is a need for standardized, digitally driven protocols to enhance precision and outcomes.

Objectives

To retrospectively evaluate the short-term clinical outcomes associated with the S-A-F-E Zygoma Protocol for guided zygomatic implant placement. Materials and methods. A retrospective clinical case series was conducted of patients who received zygomatic implants using the S-A-F-E protocol at a single center. The primary outcome was implant survival, defined as the implant being physically present and stable at the last follow-up visit. Secondary outcomes included intraoperative and postoperative complications. Data on patient demographics, implant number, and follow-up duration were collected. Only descriptive statistics were applied.

Results

A total of 27 patients received zygomatic implants. The mean follow-up duration was 18.6 months (range, 12–30 months). The implant survival rate was 100% over the observed period. One case of peri-implantitis was reported; it occurred 10 months post-loading and was managed with non-surgical debridement. No other major complications were observed.

Conclusions

Within the limitations of this retrospective case series, the S-A-F-E protocol demonstrated favorable short-term outcomes, with high implant survival and a low complication rate. Further prospective, comparative studies with long-term follow-up are necessary to validate these findings.

Zitieren

APA

Chakravarthy, A., Vinnakota, G., Chakrabarti, S., Vangaveti, R. K., & Reddy, D. (2026). The S-A-F-E zygoma protocol for guided zygomatic implant placement: a retrospective case series of 27 patients. Romanian Journal of Stomatology, 72(1), 39. https://doi.org/10.37897/rjs.2026.1.12

Vancouver

Chakravarthy A, Vinnakota G, Chakrabarti S, Vangaveti RK, Reddy D. The S-A-F-E zygoma protocol for guided zygomatic implant placement: a retrospective case series of 27 patients. Romanian Journal of Stomatology. 2026;72(1):39. doi:10.37897/rjs.2026.1.12

BibTeX
@article{Chakravarthy2026,
  author = {Chakravarthy, Akash and Vinnakota, Geyasri and Chakrabarti, Sulagna and Vangaveti, Ramya Krishna and Reddy, Deepika},
  title = {The S-A-F-E zygoma protocol for guided zygomatic implant placement: a retrospective case series of 27 patients},
  journal = {Romanian Journal of Stomatology},
  year = {2026},
  volume = {72},
  number = {1},
  pages = {39},
  doi = {10.37897/rjs.2026.1.12}
}
Kostenlos starten →