EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

PARTIAL LEAST SQUARE-ASSISTED FTIR SPECTROSCOPY FOR ROUTINE DETECTION AND QUANTIFICATION OF DRUG SUBSTANCE IN JAMU: THIAMIN HCl AS A MODEL

Ardi Nugroho, Fajar Aji Lumakso, Siti Murtafi’ah, Uzulul Hikmah

Medical Sains : Jurnal Ilmiah Kefarmasian · 18.11.2026 · 11 (4) · 485-494

DOI: 10.37874/ms.v11i4.1932 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Sains : Jurnal Ilmiah Kefarmasian, online erschienen am 18.11.2026. Verfasst von Ardi Nugroho und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The unauthorized addition of medicinal chemicals, such as thiamin HCl, to jamu pegal linu (muscle aches) by unscrupulous manufacturers poses significant health risks, as uncontrolled doses may lead to adverse side effects. This study aimed to develop a rapid analytical method for the identification and quantification of thiamin HCl in jamu pegal linu using Fourier-transform infrared (FTIR) spectroscopy coupled with partial least squares (PLS) regression. Qualitative analysis was initially performed using thin layer chromatography-densitometry to confirm the absence of thiamin HCl in the commercial samples, thereby ensuring the reliability of subsequent spiking experiments. For quantitative analysis, FTIR spectral data were processed using PLS multivariate calibration with XLSTAT software. The TLC results confirmed that none of the tested samples contained thiamin HCl. The PLS calibration model, developed using selected wavenumbers (3700, 3500, 3200, 3000, 1658, 1650, 1610, 1600, 1500, 1400, 1300, 1200, 1100, 1000, 900, 800, 700, 600, 500, and 400 cm?¹), demonstrated excellent predictive performance with a PRESS value of 0.000028751, RMSEC of 0.000446452, RMSECV of 0.00239794, and an R² of 0.9922. These validation parameters indicate a strong correlation between the actual and predicted concentrations, confirming the method's accuracy and precision. The findings demonstrate that FTIR spectroscopy combined with PLS multivariate calibration is a reliable, rapid, and non-destructive alternative for the routine analysis of thiamin HCl in herbal medicine products. Keywords: Jamu pegal linu, Thiamin HCl, FTIR spectroscopy, partial least square

Zitieren

APA

Nugroho, A., Lumakso, F. A., Murtafi’ah, S., & Hikmah, U. (2026). PARTIAL LEAST SQUARE-ASSISTED FTIR SPECTROSCOPY FOR ROUTINE DETECTION AND QUANTIFICATION OF DRUG SUBSTANCE IN JAMU: THIAMIN HCl AS A MODEL. Medical Sains : Jurnal Ilmiah Kefarmasian, 11(4), 485-494. https://doi.org/10.37874/ms.v11i4.1932

Vancouver

Nugroho A, Lumakso FA, Murtafi’ah S, Hikmah U. PARTIAL LEAST SQUARE-ASSISTED FTIR SPECTROSCOPY FOR ROUTINE DETECTION AND QUANTIFICATION OF DRUG SUBSTANCE IN JAMU: THIAMIN HCl AS A MODEL. Medical Sains : Jurnal Ilmiah Kefarmasian. 2026;11(4):485-494. doi:10.37874/ms.v11i4.1932

BibTeX
@article{Nugroho2026,
  author = {Nugroho, Ardi and Lumakso, Fajar Aji and Murtafi’ah, Siti and Hikmah, Uzulul},
  title = {PARTIAL LEAST SQUARE-ASSISTED FTIR SPECTROSCOPY FOR ROUTINE DETECTION AND QUANTIFICATION OF DRUG SUBSTANCE IN JAMU: THIAMIN HCl AS A MODEL},
  journal = {Medical Sains : Jurnal Ilmiah Kefarmasian},
  year = {2026},
  volume = {11},
  number = {4},
  pages = {485--494},
  doi = {10.37874/ms.v11i4.1932}
}
Kostenlos starten →