FIRE DANGER ASSESSMENT OF WIRES HEATING WITH STEEL CURRENT-CARRYING CONDUCTORS

A. Katunin, O. Kolomiitsev, O. Kulakov, V. Mazharov

Випробування та сертифікація · 30.06.2026 · (2(12)) · 115-120

DOI: 10.37701/ts.12.2026.13 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Випробування та сертифікація, online erschienen am 30.06.2026. Verfasst von A. Katunin und 3 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Currently, there is a pressing problem of assessing the fire danger of heating steel cable products during operation. The scope of steel cable products application can be the transmission of electrical energy and heating of industrial facilities. Assessment of the fire danger of heating steel single-core wires at different current loads. An improved mathematical model was used, which allows to estimate the temperature increase of a single-core electric wire with the time of operation. The calculations were carried out using computer equipment in the MATHCAD software package for a steel conductor. For example, the temperature-time characteristics of steel wires with polyvinyl chloride insulation were constructed for load currents less than, equal to, and greater than the maximum permissible values. Analysis of the obtained temperature-time characteristics allowed to state that the heating temperature of wires during their operation is significantly determined by the cross-section of the steel conductor. It is shown that the temperature-time characteristics have approximately the same nonlinear character at a load of 8, 14 and 20 A. The fire danger assessment of heating a single-core steel wire with polyvinyl chloride single-layer insulation based on the heat release criterion are presented. Analyzed from the point of view of fire danger, the heating temperature dependence of single-core steel wires of various cross-sections on the time of its operation at load currents less than, equal to, and greater than the maximum permissible values. The influence of the cross-section of a single-core steel wire on its heating temperature during operation at different load currents was estimated. It is shown that the lowest heating temperature and, accordingly, the lowest fire danger of heating during operation has a loaded electric wire of a larger cross-section at all considered load currents. The obtained results should be used in recommendations for determining the loads of steel wires with different cross-sections.

Zitieren

APA

Katunin, A., Kolomiitsev, O., Kulakov, O., & Mazharov, V. (2026). FIRE DANGER ASSESSMENT OF WIRES HEATING WITH STEEL CURRENT-CARRYING CONDUCTORS. Випробування та сертифікація, 115-120. https://doi.org/10.37701/ts.12.2026.13

Vancouver

Katunin A, Kolomiitsev O, Kulakov O, Mazharov V. FIRE DANGER ASSESSMENT OF WIRES HEATING WITH STEEL CURRENT-CARRYING CONDUCTORS. Випробування та сертифікація. 2026:115-120. doi:10.37701/ts.12.2026.13

BibTeX
@article{Katunin2026,
  author = {Katunin, A. and Kolomiitsev, O. and Kulakov, O. and Mazharov, V.},
  title = {FIRE DANGER ASSESSMENT OF WIRES HEATING WITH STEEL CURRENT-CARRYING CONDUCTORS},
  journal = {Випробування та сертифікація},
  year = {2026},
  number = {2(12)},
  pages = {115--120},
  doi = {10.37701/ts.12.2026.13}
}
Kostenlos starten →