Integrated Analysis of Lock-In Thermography, X-Ray Computed Tomography, and Scanning Electron Microscopy for Rapid Screening and Characterization of Defects in High-Density Semiconductor Packages
Pan Pacific Symposium · 2026-02 · 29 (1) · 150-154
DOI: 10.37665/ppenwxn45180 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pan Pacific Symposium, 2026-02. Verfasst von Yuji Inui und 6 weiteren Autor:innen.
Abstract (Originalsprache)
In this study, the reliability of solder ball interconnections between a 100 mm square core substrate and a motherboard was evaluated by thermal cycle test (TCT). After 1000 cycles of the TCT, defects in solder balls were investigated by integrated analysis combining lock-in thermography (LIT), X-ray computed tomography (X-ray CT), and scanning electron microscopy (SEM). On LIT phase response maps acquired after TCT, regions interpreted as open circuits were identified. The LIT-indicated open areas were examined by X-ray CT to determine their three-dimensional internal morphology, and they were further analyzed by SEM to confirm the defect details. The combined analysis indicated that the defects were due to a lack of wettability between the solder balls and the pads.
Zitieren
APA
Inui, Y., Kan, D., Takahashi, M., Aoyama, M., Matsuo, N., Isomura, S., & Katoh, S. (2026). Integrated Analysis of Lock-In Thermography, X-Ray Computed Tomography, and Scanning Electron Microscopy for Rapid Screening and Characterization of Defects in High-Density Semiconductor Packages. Pan Pacific Symposium, 29(1), 150-154. https://doi.org/10.37665/ppenwxn45180
Vancouver
Inui Y, Kan D, Takahashi M, Aoyama M, Matsuo N, Isomura S, et al. Integrated Analysis of Lock-In Thermography, X-Ray Computed Tomography, and Scanning Electron Microscopy for Rapid Screening and Characterization of Defects in High-Density Semiconductor Packages. Pan Pacific Symposium. 2026;29(1):150-154. doi:10.37665/ppenwxn45180
BibTeX
@article{Inui2026,
author = {Inui, Yuji and Kan, Donchoru and Takahashi, Masaki and Aoyama, Motoo and Matsuo, Nao. and Isomura, Sojiro and Katoh, Sadaaki},
title = {Integrated Analysis of Lock-In Thermography, X-Ray Computed Tomography, and Scanning Electron Microscopy for Rapid Screening and Characterization of Defects in High-Density Semiconductor Packages},
journal = {Pan Pacific Symposium},
year = {2026},
volume = {29},
number = {1},
pages = {150--154},
doi = {10.37665/ppenwxn45180}
}