EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Thermal and luminic comfort assessment in university classrooms in Tijuana, Baja California. Case of study FCITEC, Valle de las Palmas

María Teresa De la Cruz Chaidez, José Francisco Armendáriz López, Francisco José Martín del Campo Saray, Miguel Isaac Sahagún Valenzuela, María Cristina Castañón Bautista, Carmen García Gómez

REVISTA DE CIENCIAS TECNOLÓGICAS · 30.12.2022 · 5 (4) · e233

DOI: 10.37636/recit.v5n4e233 ↗

Kurz gefasst

Fachartikel in der Zeitschrift REVISTA DE CIENCIAS TECNOLÓGICAS, online erschienen am 30.12.2022. Verfasst von María Teresa De la Cruz Chaidez und 5 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

About 2022, studies on environmental conditions inside classrooms have increased because they are related to well-being, performance, and student productivity in terms of concentration, attention, and learning during school hours. Assessing the conditions of the educational space once inhabited can be fundamental to identifying environmental adjustments that could improve achievement in learning through design strategies in school facilities in the locality. The evaluation of the thermal and luminic conditions of three classrooms designed to function with natural ventilation, in two buildings of the Universidad Autónoma of Baja California, in Tijuana, Mexico, during the cold-warm transition period is presented. Physical measurements of environmental indicators were made, including temperature, relative humidity, and daylight. A total of 181 students completed the environmental survey questionnaires. This study aimed to evaluate the interior environmental space conditions and determine the influence on occupants' comfort. Results showed that more than 50% of the students were in a thermal discomfort situation when the temperature was out of the range of 19.7°C -27.7° C, consistent with the application of the ASHRAE Adaptative Comfort Zones. Daylight values were below the minimum required of 300 Lux for educational classroom specificity in [1, 2] of the three classrooms. Building's orientations, West and South registered illuminance values that could produce glare and increase thermal discomfort due to high solar radiation. The results confirmed the close relationship between environmental conditions and students' comfort in classrooms.

Zitieren

APA

Chaidez, M. T. D. L. C., López, J. F. A., Saray, F. J. M. D. C., Valenzuela, M. I. S., Bautista, M. C. C., & Gómez, C. G. (2022). Thermal and luminic comfort assessment in university classrooms in Tijuana, Baja California. Case of study FCITEC, Valle de las Palmas. REVISTA DE CIENCIAS TECNOLÓGICAS, 5(4), e233. https://doi.org/10.37636/recit.v5n4e233

Vancouver

Chaidez MTDLC, López JFA, Saray FJMDC, Valenzuela MIS, Bautista MCC, Gómez CG. Thermal and luminic comfort assessment in university classrooms in Tijuana, Baja California. Case of study FCITEC, Valle de las Palmas. REVISTA DE CIENCIAS TECNOLÓGICAS. 2022;5(4):e233. doi:10.37636/recit.v5n4e233

BibTeX
@article{Chaidez2022,
  author = {Chaidez, María Teresa De la Cruz and López, José Francisco Armendáriz and Saray, Francisco José Martín del Campo and Valenzuela, Miguel Isaac Sahagún and Bautista, María Cristina Castañón and Gómez, Carmen García},
  title = {Thermal and luminic comfort assessment in university classrooms in Tijuana, Baja California. Case of study FCITEC, Valle de las Palmas},
  journal = {REVISTA DE CIENCIAS TECNOLÓGICAS},
  year = {2022},
  volume = {5},
  number = {4},
  pages = {e233},
  doi = {10.37636/recit.v5n4e233}
}