High-Fidelity CT-on-Rails-Based Characterization of Delivered Dose Variation in Conformal Head and Neck Treatments
Applied Radiation Oncology · 2023
DOI: 10.37549/aro-d-23-00013 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Radiation Oncology, 2023. Verfasst von Haocheng Dai und 6 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben.
Abstract (Originalsprache)
Objective
This study aims to characterize dose variations from the original plan for a cohort of patients with head and neck cancer (HNC) using high-quality CT on rails (CTOR) datasets and evaluate a predictive model for identifying patients needing replanning. Materials and Methods: In total, 74 patients with HNC treated on our CTOR-equipped machine were evaluated in this retrospective study. Patients were treated at our facility using in-room, CTOR image guidance—acquiring CTOR kV fan-beam CT images on a weekly to near-daily basis. For each patient, a particular day’s treatment dose was calculated by applying the approved, planned beam set to the postimage-guided alignment CT image of the day. Total accumulated delivered dose distributions were calculated and compared with the planned dose distribution, and differences were characterized by comparison of dose and biological response statistics.
Results
The majority of patients in the study saw excellent agreement between planned and delivered dose distribution in targets—the mean deviations of dose received by 95% and 98% of the planning target volumes of the cohort are −0.7% and −1.3%, respectively. In critical organs, we saw a +6.5% mean deviation of mean dose in the parotid glands, −2.3% mean deviation of maximum dose in the brainstem, and +0.7% mean deviation of maximum dose in the spinal cord. Of 74 patients, 10 experienced nontrivial variation of delivered parotid dose, which resulted in a normal tissue complication probability (NTCP) increase compared with the anticipated NTCP in the original plan, ranging from 11% to 44%.
Conclusion
We determined that a midcourse evaluation of dose deviation was not effective in predicting the need for replanning for our patient cohorts. The observed nontrivial dose difference to the parotid gland delivered dose suggests that even when rigorous, high-quality image guidance is performed, clinically concerning variations to predicted dose delivery can still occur.
Zitieren
APA
Dai, H., Sarkar, V., Dial, C., Foote, M. D., Hitchcock, Y., Joshi, S., & Salter, B. J. (2023). High-Fidelity CT-on-Rails-Based Characterization of Delivered Dose Variation in Conformal Head and Neck Treatments. Applied Radiation Oncology. https://doi.org/10.37549/aro-d-23-00013
Vancouver
Dai H, Sarkar V, Dial C, Foote MD, Hitchcock Y, Joshi S, et al. High-Fidelity CT-on-Rails-Based Characterization of Delivered Dose Variation in Conformal Head and Neck Treatments. Applied Radiation Oncology. 2023. doi:10.37549/aro-d-23-00013
BibTeX
@article{Dai2023,
author = {Dai, Haocheng and Sarkar, Vikren and Dial, Christian and Foote, Markus D. and Hitchcock, Ying and Joshi, Sarang and Salter, Bill J.},
title = {High-Fidelity CT-on-Rails-Based Characterization of Delivered Dose Variation in Conformal Head and Neck Treatments},
journal = {Applied Radiation Oncology},
year = {2023},
doi = {10.37549/aro-d-23-00013}
}
EUVIMED