Background
Graves' ophthalmopathy (GO) is associated with structural and functional orbital changes that may influence intraocular pressure (IOP) and complicate its accurate measurement. Reliable IOP assessment is essential for timely diagnosis of ocular hypertension and prevention of glaucomatous damage; however, the performance of different tonometry methods in GO patients remains insufficiently studied.
Objective
To perform a comparative analysis of IOP measurements obtained using different tonometry methods in patients with GO and ocular hypertension, and to evaluate the variability between these methods.
Methods
A cohort comparative study was conducted between 2021 and 2024 at the Republican Specialized Scientific and Practical Center of Endocrinology. The study included patients with GO and ocular hypertension (n = 38). IOP was measured using Goldmann applanation tonometry, non-contact tonometry, and the Maklakov tonometer. Statistical analysis included calculation of mean values, standard deviation, and comparison using Student’s t-test, with p < 0.05 considered statistically significant.
Results
The highest IOP values were obtained using the Maklakov method (29.5±3.5 mmHg), compared to Goldmann applanation tonometry (23.2±2.1 mmHg) and non-contact tonometry (22.9±2.3 mmHg). Significant differences were found between Maklakov and Goldmann methods (p
Zitieren
APA
R.A, Z., & R.Sh., M. (2026). Comparative Assessment of Intraocular Pressure Measurement Methods in Patients with Graves’ Ophthalmopathy And Ocular Hypertension. International Journal of Medical Sciences And Clinical Research, 06(04), 40-44. https://doi.org/10.37547/ijmscr/volume06issue04-06
Vancouver
R.A Z, R.Sh. M. Comparative Assessment of Intraocular Pressure Measurement Methods in Patients with Graves’ Ophthalmopathy And Ocular Hypertension. International Journal of Medical Sciences And Clinical Research. 2026;06(04):40-44. doi:10.37547/ijmscr/volume06issue04-06
BibTeX
@article{RA2026,
author = {R.A, Zakirkhodjayev . and R.Sh., Makhmudov},
title = {Comparative Assessment of Intraocular Pressure Measurement Methods in Patients with Graves’ Ophthalmopathy And Ocular Hypertension},
journal = {International Journal of Medical Sciences And Clinical Research},
year = {2026},
volume = {06},
number = {04},
pages = {40--44},
doi = {10.37547/ijmscr/volume06issue04-06}
}
EUVIMED