Effect of Therapeutic Electrical Stimulation on Agonist Versus Antagonist Muscle on Spasticity In Patients with Cerebral Palsy – A Randomized Controlled Trial
Indian Journal of Physiotherapy and Occupational Therapy - An International Journal · 18.07.2026 · 20 (3) · 81-89
DOI: 10.37506/95wrvp72 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Indian Journal of Physiotherapy and Occupational Therapy - An International Journal, online erschienen am 18.07.2026. Verfasst von Hinal Patel und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Cerebral palsy is one of the most common neurological disorders leading to disability. A hallmark of CP is spasticity. Spasticity leads to movement limitations and thus, largely contributes to the disruption of motor performance. To decrease the spasticity various physiotherapy techniques are used.
Objective
To compare the effect of therapeutic electrical stimulation on agonist versus antagonist muscle on plantar flexors’ spasticity in patient with spastic diplegic cerebral palsy.
Methods
In the present comparative interventional study, total 33 patients were participated. Out of which 17 patients were randomly allocated in group A and 16 patients to group B. Group A received Therapeutic electrical stimulation of agonist muscle + conventional physiotherapy and Group B received Therapeutic electrical stimulation of antagonist muscle + conventional physiotherapy. As per inclusion and exclusion criteria and treatment was given for the duration of 20 minute, 5 days per week for 4 weeks. Pre and post intervention assessment were carried out by using Modified Tardieu scale and Hmax / Mmax ratio. Data was collected and analyzed. Results:Agonist muscle group shows significant difference in Hmax / Mmax ratio (p=0.032), and antagonist muscle group shows significant improvement in Dynamic component of MTS and Hmax / Mmax ratio (p=0.000), whereas no difference found in quality of muscle reaction. Antagonist muscle shows significant difference in Dynamic component of MTS and Hmax / Mmax ratio (p=0.001).
Conclusion
This study concludes that therapeutic electrical stimulation of the antagonist muscle is more effective for reduction of spasticity.
Zitieren
APA
Patel, H., & Desai, A. (2026). Effect of Therapeutic Electrical Stimulation on Agonist Versus Antagonist Muscle on Spasticity In Patients with Cerebral Palsy – A Randomized Controlled Trial. Indian Journal of Physiotherapy and Occupational Therapy - An International Journal, 20(3), 81-89. https://doi.org/10.37506/95wrvp72
Vancouver
Patel H, Desai A. Effect of Therapeutic Electrical Stimulation on Agonist Versus Antagonist Muscle on Spasticity In Patients with Cerebral Palsy – A Randomized Controlled Trial. Indian Journal of Physiotherapy and Occupational Therapy - An International Journal. 2026;20(3):81-89. doi:10.37506/95wrvp72
BibTeX
@article{Patel2026,
author = {Patel, Hinal and Desai, Anjan},
title = {Effect of Therapeutic Electrical Stimulation on Agonist Versus Antagonist Muscle on Spasticity In Patients with Cerebral Palsy – A Randomized Controlled Trial},
journal = {Indian Journal of Physiotherapy and Occupational Therapy - An International Journal},
year = {2026},
volume = {20},
number = {3},
pages = {81--89},
doi = {10.37506/95wrvp72}
}
EUVIMED