Magnetic resonance imaging-based deep learning model to predict multiple firings in double-stapled colorectal anastomosis
World Journal of Gastroenterology · 2023
DOI: 10.3748/wjg.v29.i3.536 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift World Journal of Gastroenterology, 2023. Verfasst von Zheng-Hao Cai und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China. Hauptthemen laut MEDLINE: Deep Learning, Rectal Neoplasms, Laparoscopy. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND: Multiple linear stapler firings during double stapling technique (DST) after laparoscopic low anterior resection (LAR) are associated with an increased risk of anastomotic leakage (AL). However, it is difficult to predict preoperatively the need for multiple linear stapler cartridges during DST anastomosis. AIM: To develop a deep learning model to predict multiple firings during DST anastomosis based on pelvic magnetic resonance imaging (MRI). METHODS: We collected 9476 MR images from 328 mid-low rectal cancer patients undergoing LAR with DST anastomosis, which were randomly divided into a training set (n = 260) and testing set (n = 68). Binary logistic regression was adopted to create a clinical model using six factors. The sequence of fast spin-echo T2-weighted MRI of the entire pelvis was segmented and analyzed. Pure-image and clinical-image integrated deep learning models were constructed using the mask region-based convolutional neural network segmentation tool and three-dimensional convolutional networks. Sensitivity, specificity, accuracy, positive predictive value (PPV), and area under the receiver operating characteristic curve (AUC) was calculated for each model. RESULTS: The prevalence of ≥ 3 linear stapler cartridges was 17.7% (58/328). The prevalence of AL was statistically significantly higher in patients with ≥ 3 cartridges compared to those with ≤ 2 cartridges (25.0% vs 11.8%, P = 0.018). Preoperative carcinoembryonic antigen level > 5 ng/mL (OR = 2.11, 95%CI 1.08-4.12, P = 0.028) and tumor size ≥ 5 cm (OR = 3.57, 95%CI 1.61-7.89, P = 0.002) were recognized as independent risk factors for use of ≥ 3 linear stapler cartridges. Diagnostic performance was better with the integrated model (accuracy = 94.1%, PPV = 87.5%, and AUC = 0.88) compared with the clinical model (accuracy = 86.7%, PPV = 38.9%, and AUC = 0.72) and the image model (accuracy = 91.2%, PPV = 83.3%, and AUC = 0.81). CONCLUSION: MRI-based deep learning model can predict the use of ≥ 3 linear stapler cartridges during DST anastomosis in laparoscopic LAR surgery. This model might help determine the best anastomosis strategy by avoiding DST when there is a high probability of the need for ≥ 3 linear stapler cartridges.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of General Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China.
- Shanghai Minimally Invasive Surgery Center, Shanghai 200025, China.
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 201100, China.
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China.
- Department of General Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China. marsnew1997@163.com.
Zitieren
APA
Cai, Z. H., Zhang, Q., Fu, Z. W., Fingerhut, A., Tan, J. W., Zang, L., Dong, F., Li, S. C., Wang, S. L., & Ma, J. J. (2023). Magnetic resonance imaging-based deep learning model to predict multiple firings in double-stapled colorectal anastomosis. World Journal of Gastroenterology. https://doi.org/10.3748/wjg.v29.i3.536
Vancouver
Cai ZH, Zhang Q, Fu ZW, Fingerhut A, Tan JW, Zang L, et al. Magnetic resonance imaging-based deep learning model to predict multiple firings in double-stapled colorectal anastomosis. World Journal of Gastroenterology. 2023. doi:10.3748/wjg.v29.i3.536
BibTeX
@article{Cai2023,
author = {Cai, Zheng-Hao and Zhang, Qun and Fu, Zhan-Wei and Fingerhut, Abraham and Tan, Jing-Wen and Zang, Lu and Dong, Feng and Li, Shu-Chun and Wang, Shi-Lin and Ma, Jun-Jun},
title = {Magnetic resonance imaging-based deep learning model to predict multiple firings in double-stapled colorectal anastomosis},
journal = {World Journal of Gastroenterology},
year = {2023},
doi = {10.3748/wjg.v29.i3.536}
}
EUVIMED