EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Toughness Energy Comparison of Jute, E-Glass, and Hybrid-Wrapped Concrete Columns under Compression

Achmad Jusuf Zulfikar, Siswo Pranoto, Zakir Husin, Ibnu Hajar, Suardi

JTTM : Jurnal Terapan Teknik Mesin · 30.09.2026 · 7 (2) · 402-410

DOI: 10.37373/jttm.v7i2.2646 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JTTM : Jurnal Terapan Teknik Mesin, online erschienen am 30.09.2026. Verfasst von Achmad Jusuf Zulfikar und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Concrete columns are inherently brittle and possess limited capacity to absorb energy before failure, making external composite confinement a promising method for improving their structural toughness under axial compression. This study aimed to compare the toughness energy of cylindrical concrete columns wrapped with jute, E-glass, and hybrid jute/E-glass/epoxy laminates, evaluate the effects of layer number and stacking sequence, and identify the most effective three-layer configuration. Cylindrical specimens were prepared as an unconfined control (S0), jute-wrapped configurations with one to three layers (J, JJ, and JJJ), hybrid three-layer configurations (GGJ, JGJ, and JJG), and a three-layer E-glass configuration (GGG). Axial compression tests were conducted in accordance with ASTM C39, with three repetitions for each variation. Toughness energy was determined from the area under the load–displacement curve using an image-based histogram method in Adobe Photoshop, and the results were statistically validated through one-way ANOVA. The control specimen exhibited an average toughness energy of 86.81 J, whereas JGJ achieved the highest value of 649.44 J, followed by GGJ at 645.98 J and JJJ at 568.27 J. In contrast, J and GGG produced 32.62 and 174.76 J, respectively. These findings demonstrate that toughness energy depends strongly on laminate thickness and stacking sequence, with alternating hybrid arrangements providing the most effective confinement and energy absorption.

Zitieren

APA

Zulfikar, A. J., Pranoto, S., Husin, Z., Hajar, I., & Suardi (2026). Toughness Energy Comparison of Jute, E-Glass, and Hybrid-Wrapped Concrete Columns under Compression. JTTM : Jurnal Terapan Teknik Mesin, 7(2), 402-410. https://doi.org/10.37373/jttm.v7i2.2646

Vancouver

Zulfikar AJ, Pranoto S, Husin Z, Hajar I, Suardi. Toughness Energy Comparison of Jute, E-Glass, and Hybrid-Wrapped Concrete Columns under Compression. JTTM : Jurnal Terapan Teknik Mesin. 2026;7(2):402-410. doi:10.37373/jttm.v7i2.2646

BibTeX
@article{Zulfikar2026,
  author = {Zulfikar, Achmad Jusuf and Pranoto, Siswo and Husin, Zakir and Hajar, Ibnu and Suardi},
  title = {Toughness Energy Comparison of Jute, E-Glass, and Hybrid-Wrapped Concrete Columns under Compression},
  journal = {JTTM : Jurnal Terapan Teknik Mesin},
  year = {2026},
  volume = {7},
  number = {2},
  pages = {402--410},
  doi = {10.37373/jttm.v7i2.2646}
}
Kostenlos starten →