EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Computational Fluid Dynamics (CFD) Study on the Effect of Outlet Number and Dimensions of Air Supply Ducting on Air Flow Distribution in Passenger Train

Septian Reza Kurniawan, Rangga Adhyatmika, Mega Rahayu Nur Kusuma Wardhani, Nanang Romandhoni, Agus Choirul Arifin, Oky Bayu Murdianto

Jurnal Perkeretaapian Indonesia (Indonesian Railway Journal) · 2026

DOI: 10.37367/jpi.v10i2.541 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Jurnal Perkeretaapian Indonesia (Indonesian Railway Journal), 2026. Verfasst von Septian Reza Kurniawan und 5 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Along with population growth, the demand for comfort in public transportation such as buses, trams, and trains continues to increase. To ensure passenger comfort, the Heating, Ventilation, and Air Conditioning (HVAC) system must provide proper air temperature and flow conditions. This study aims to investigate the influence of the number of outlets and ducting dimensions of air supply systems in passenger trains on airflow performance, as well as to analyze the distribution of pressure and velocity inside the ducting. The simulation was carried out using the Computational Fluid Dynamics (CFD) method with Ansys Fluent 2022 R1. The model employed a mesh size of 0.025 m, pressure-based solver under steady-state conditions, k-ε turbulence model, and air modeled as an ideal gas (ρ = 1.225 kg/m³). Boundary conditions consisted of a mass flow inlet of 0.6 kg/s and a pressure outlet. The results showed that ducting dimension variations produced an average airflow of 478 cmh, while outlet number variations resulted in an average of 461 cmh. Airflow increased with velocity as long as no significant obstructions were present. Variable A achieved stable velocities of 13–20 m/s with pressure between 0–50 Pa, while Variable F demonstrated more consistent distribution at around 15 m/s with lower pressure, 0–30 Pa. Overall, gradual adjustments in outlet number and ducting dimensions positively enhanced airflow capacity and distribution quality within the train cabin

Zitieren

APA

Kurniawan, S. R., Adhyatmika, R., Wardhani, M. R. N. K., Romandhoni, N., Arifin, A. C., & Murdianto, O. B. (2026). Computational Fluid Dynamics (CFD) Study on the Effect of Outlet Number and Dimensions of Air Supply Ducting on Air Flow Distribution in Passenger Train. Jurnal Perkeretaapian Indonesia (Indonesian Railway Journal). https://doi.org/10.37367/jpi.v10i2.541

Vancouver

Kurniawan SR, Adhyatmika R, Wardhani MRNK, Romandhoni N, Arifin AC, Murdianto OB. Computational Fluid Dynamics (CFD) Study on the Effect of Outlet Number and Dimensions of Air Supply Ducting on Air Flow Distribution in Passenger Train. Jurnal Perkeretaapian Indonesia (Indonesian Railway Journal). 2026. doi:10.37367/jpi.v10i2.541

BibTeX
@article{Kurniawan2026,
  author = {Kurniawan, Septian Reza and Adhyatmika, Rangga and Wardhani, Mega Rahayu Nur Kusuma and Romandhoni, Nanang and Arifin, Agus Choirul and Murdianto, Oky Bayu},
  title = {Computational Fluid Dynamics (CFD) Study on the Effect of Outlet Number and Dimensions of Air Supply Ducting on Air Flow Distribution in Passenger Train},
  journal = {Jurnal Perkeretaapian Indonesia (Indonesian Railway Journal)},
  year = {2026},
  doi = {10.37367/jpi.v10i2.541}
}