Assessment of Occupational Safety and Health Status in Kenyan Solar Electricity Production Facilities of 40 Megawatts and Above
East African Journal of Health and Science · 29.07.2026 · 9 (3) · 67-79
DOI: 10.37284/eajhs.9.3.5443 ↗Kurz gefasst
Fachartikel in der Zeitschrift East African Journal of Health and Science, online erschienen am 29.07.2026. Verfasst von Rita Wanjiku Mwadime und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The electricity production sector in Kenya supports its industrial development blueprint, The Vision 2030. Kenya is endowed with abundant solar energy resource0s and solar power generation is growing at a projected 15% annually, increasing worker exposure to occupational safety and health (OSH) hazards. This study assessed occupational safety and health status in Kenyan solar electricity production facilities of 40MW and above, focusing on hazard identification, OSH protective measures, and incident occurrence. A descriptive research design was employed. The study targeted 125 workers across four solar facilities in Kilifi and Uasin Gishu Counties. Data were collected using a pretested questionnaire and observation checklist. Quantitative data was analysed using descriptive statistics. The findings established that the facilities face a dual-natured hazard profile combining common technical risks in such facilities with localised hazards dependent on geographical location. The study found that physical hazards dominate, constituting approximately 80% of all identified hazards, with electricity and fire most prevalent. Snakes and extreme heat were predominant in hot and arid locations. OSH protective measures were found to exist in the form of OSH policies, PPE, emergency shutdown (ESD) devices, safety procedures and training. The study identified significant gaps in risk assessments, emergency preparedness for climate-related events, OSH committee functionality, and safety incentive programs. Poor safety attitude among workers emerged as the key barrier to effective OSH implementation. Only minor injuries were recorded, with no fatalities or serious injuries. The average minor incident rate was 11.5 per 200,000 work hours. The study concludes that existing foundational safety measures provide basic protection. However, critical gaps exist in systemic OSH management, leaving the facilities vulnerable to serious incidents as operations continue and expand. The study recommends safety attitude training, comprehensive and regular risk assessments, climate-resilient safety planning, strengthening of OSH committees and recognition of good OSH performance.
Zitieren
APA
Mwadime, R. W., Mburu, C., & Xavier, F. (2026). Assessment of Occupational Safety and Health Status in Kenyan Solar Electricity Production Facilities of 40 Megawatts and Above. East African Journal of Health and Science, 9(3), 67-79. https://doi.org/10.37284/eajhs.9.3.5443
Vancouver
Mwadime RW, Mburu C, Xavier F. Assessment of Occupational Safety and Health Status in Kenyan Solar Electricity Production Facilities of 40 Megawatts and Above. East African Journal of Health and Science. 2026;9(3):67-79. doi:10.37284/eajhs.9.3.5443
BibTeX
@article{Mwadime2026,
author = {Mwadime, Rita Wanjiku and Mburu, Charles and Xavier, Francis},
title = {Assessment of Occupational Safety and Health Status in Kenyan Solar Electricity Production Facilities of 40 Megawatts and Above},
journal = {East African Journal of Health and Science},
year = {2026},
volume = {9},
number = {3},
pages = {67--79},
doi = {10.37284/eajhs.9.3.5443}
}
EUVIMED