Kurz gefasst

Fachartikel in der Zeitschrift East African Journal of Engineering, online erschienen am 20.11.2026. Verfasst von Danford William Kafumu und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study examined how demand uncertainty, consistent energy accounting, and storage selection affected the appraisal of hybrid photovoltaic (PV) and solar thermal water heating for a 31-room commercial hotel in Dodoma, Tanzania. We audited an existing site-inventory workbook and dissertation, reproduced their calculations in Python, and compared alternative heating configurations using a continuous synthetic year with explicit tank losses, PV temperature effects, a storage high-limit, and power-limited auxiliary heating. The estimated volume of 2,110 L/day required 88.3 kWh/day when heated from 24 to 60°C; calendar integration of twelve supplied inlet-temperature scenarios gave 32.7 MWh/year. Interpreting the same volume as mixed water at 40°C reduced the reference requirement to 39.3 kWh/day. Correcting the irradiation–irradiance error yielded 25.7–32.4 kWh/day of potential PV energy delivered to the selected array. A battery-free configuration with 28.7 m² of collectors and approximately 1.06 m³ of thermal storage supplied 82.2% of annual useful heat from renewable sources, but retained temperature-service shortfalls under the assumed draw peaks. Against a modelled existing-solar baseline, its conditional net present value was TSh 25.5 million, compared with −TSh 32.5 million for the battery alternative. Missing tank, safety, and backup quotations made these financial results conditional. Combined financial scenarios reversed the conclusion on the battery-free investment. The findings support comparing demand boundaries and thermal storage before purchasing batteries; without measured hourly inputs, it is not possible to establish actual hotel performance or a final procurement design.

Zitieren

APA

Kafumu, D. W., Mwakitalima, I. J., & Mlela, M. K. (2026). Thermal Demand and Conditional Economic Appraisal of Hybrid PV and Solar Thermal Water Heating in a Dodoma Hotel. East African Journal of Engineering, 9(2), 307-326. https://doi.org/10.37284/eaje.9.2.6351

Vancouver

Kafumu DW, Mwakitalima IJ, Mlela MK. Thermal Demand and Conditional Economic Appraisal of Hybrid PV and Solar Thermal Water Heating in a Dodoma Hotel. East African Journal of Engineering. 2026;9(2):307-326. doi:10.37284/eaje.9.2.6351

BibTeX
@article{Kafumu2026,
  author = {Kafumu, Danford William and Mwakitalima, Isaka Jackson and Mlela, Masoud Kamoleka},
  title = {Thermal Demand and Conditional Economic Appraisal of Hybrid PV and Solar Thermal Water Heating in a Dodoma Hotel},
  journal = {East African Journal of Engineering},
  year = {2026},
  volume = {9},
  number = {2},
  pages = {307--326},
  doi = {10.37284/eaje.9.2.6351}
}