Inter-Segmental Trunk Kinematics Differ Between Wheelchair Athletes with High and Low Trunk Function: An Exploratory Analysis Using Two Inertial Measurement Units
Acta of Bioengineering and Biomechanics · 02.07.2026 · 28 (2)
DOI: 10.37190/abb/224696 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta of Bioengineering and Biomechanics, online erschienen am 02.07.2026. Verfasst von Kajetan Ciunelis und 6 weiteren Autor:innen. Beteiligte Einrichtung: PhD School, Józef Piłsudski University of Physical Education in Warsaw, Warsaw, Poland. Hauptthemen laut MEDLINE: Wheelchairs, Torso, Athletes.
Abstract (Originalsprache)
Purpose
This study examined whether upper and mid trunk kinematics, measured by inertial measurement units at seventh cervical (C7) and eighth thoracic (T8) vertebral levels, distinguish between clinically defined levels of trunk function to support classifiers’ decisions in Paralympic sports.
Methods
Sixty-three wheelchair athletes with neuromusculoskeletal impairment (54 wheelchair basketball players, 7 fencers and 2 other) were classified into four trunk-hip function groups (Very Low, Low, Moderate, High) using hierarchical cluster analysis based on the composite score of standardized Manual Muscle Testing of trunk and hip muscles. Participants performed maximum active range of motion (Volume of Action) tasks while sitting in four conditions with progressively reduced external support (Full, Partial, No Support, and Sport Wheelchair). Two IMUs recorded trunk kinematics at 100 Hz. Inter-segmental peak angular differences between sensors were compared across groups using Kruskal-Wallis tests.
Results
Active range of motion from individual C7 and T8 sensors differentiated most trunk-hip function group pairs (88% of comparisons). Peak trunk angle differed between sensors in 66% of comparisons, particularly for rotation (8–20°) and lateral tilt (4–14°). These inter-segmental C7-T8 differences separated groups in 23% of comparisons (mean difference 10°; range 5–20°).
Conclusions
Active range of motion from a single upper trunk (C7) sensor discriminated between most trunk function group pairs and appears sufficient for classification. Inter-segmental C7-T8 trunk peak angle differences provided limited additional classification value beyond single-sensor measurements, supporting the use of simplified field assessment protocols.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- PhD School, Józef Piłsudski University of Physical Education in Warsaw, Warsaw, Poland.
- Faculty of Rehabilitation, Józef Piłsudski University of Physical Education in Warsaw, Warsaw, Poland.
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.
- Department of Physiology, Nutrition, and Biomechanics, The Swedish School of Sport and Health Sciences (GIH), Stockholm, Sweden.
- Department of Health Sciences, The Swedish Winter Sports Research Centre, Mid Sweden University, Östersund, Sweden.
- Department of Neuroscience, Karolinska Institute, Stockholm, Sweden.
ORCID-Profile: Kajetan Ciunelis
Zitieren
APA
Ciunelis, K., Błażkiewicz, M., Digo, E., Marszałek, J., Ohlsson, M. L., Bjerkefors, A., & Vanlandewijck, Y. (2026). Inter-Segmental Trunk Kinematics Differ Between Wheelchair Athletes with High and Low Trunk Function: An Exploratory Analysis Using Two Inertial Measurement Units. Acta of Bioengineering and Biomechanics, 28(2). https://doi.org/10.37190/abb/224696
Vancouver
Ciunelis K, Błażkiewicz M, Digo E, Marszałek J, Ohlsson ML, Bjerkefors A, et al. Inter-Segmental Trunk Kinematics Differ Between Wheelchair Athletes with High and Low Trunk Function: An Exploratory Analysis Using Two Inertial Measurement Units. Acta of Bioengineering and Biomechanics. 2026;28(2). doi:10.37190/abb/224696
BibTeX
@article{Ciunelis2026,
author = {Ciunelis, Kajetan and Błażkiewicz, Michalina and Digo, Elisa and Marszałek, Jolanta and Ohlsson, Marie Lund and Bjerkefors, Anna and Vanlandewijck, Yves},
title = {Inter-Segmental Trunk Kinematics Differ Between Wheelchair Athletes with High and Low Trunk Function: An Exploratory Analysis Using Two Inertial Measurement Units},
journal = {Acta of Bioengineering and Biomechanics},
year = {2026},
volume = {28},
number = {2},
doi = {10.37190/abb/224696}
}
EUVIMED