EUVIMEDEUVIMED entdecken
Crossref

Usefulness of the Instrumented Timed Up and Go Test for Walking Assessment in Older Adults

Piotr Szaflik iD, Katarzyna Nowakowska-Lipiec, Hanna Zadoń, Robert Michnik

Acta of Bioengineering and Biomechanics · 15.06.2026 · 28 (2)

DOI: 10.37190/abb/224360 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta of Bioengineering and Biomechanics, online erschienen am 15.06.2026. Verfasst von Piotr Szaflik und 3 weiteren Autor:innen. Beteiligte Einrichtung: Silesian University of Technology, Faculty of Biomedical Engineering, Department of Biomechatronics, Zabrze, Poland. Hauptthemen laut MEDLINE: Walking.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The Up and Go test is a widely used tool among physical therapists for assessing functional mobility. Advances in inertial measurement unit sensors (IMU) enable the analysis not only of total walk duration, but also of the duration of individual walk phases, as well as the determination of spatiotemporal and kinematic parameters for each phase. Consequently, the IMU-supported version of the test up and go, referred to as the instrumented up and go, enables a substantially more comprehensive analysis of locomotor patterns. The aim of this study was to evaluate the extent to which spatiotemporal and kinematic parameters obtained during the instrumented timed up nad go test correspond to those observed during walking in older adults.

Methods

The study included 30 adults aged over 60 years, who performed the instrumented up and go test as well as a 10-m walk test at a self-selected walking speed. The study involved the analysis of selected spatiotemporal parameters, including cadence, velocity, stride length, and the percentage contribution of gait phases, as well as analysis of pelvic tilt and lower-limb kinematics, including ranges of motion.

Results

The results indicate that while the instrumented up and go test does not directly reflect natural walk patterns, selected parameters may still provide complementary information relevant to functional mobility assessment in older adults.

Conclusions

The instrumented up and go test should not be considered a substitute for standard walk analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WalkingHumansBiomechanical PhenomenaAgedFemaleMaleGaitTime FactorsMiddle Aged

Stichwörter der Autor:innen

AgingInertial sensorsOlder adultsTimed Up and Go testWalk assessmentiTUG

Autor:innen und Institutionen

  • Silesian University of Technology, Faculty of Biomedical Engineering, Department of Biomechatronics, Zabrze, Poland.
  • Independent Researcher, Zabrze, Poland.

ORCID-Profile: Piotr Szaflik

Zitieren

APA

Szaflik, P., Nowakowska-Lipiec, K., Zadoń, H., & Michnik, R. (2026). Usefulness of the Instrumented Timed Up and Go Test for Walking Assessment in Older Adults. Acta of Bioengineering and Biomechanics, 28(2). https://doi.org/10.37190/abb/224360

Vancouver

Szaflik P, Nowakowska-Lipiec K, Zadoń H, Michnik R. Usefulness of the Instrumented Timed Up and Go Test for Walking Assessment in Older Adults. Acta of Bioengineering and Biomechanics. 2026;28(2). doi:10.37190/abb/224360

BibTeX
@article{Szaflik2026,
  author = {Szaflik, Piotr and Nowakowska-Lipiec, Katarzyna and Zadoń, Hanna and Michnik, Robert},
  title = {Usefulness of the Instrumented Timed Up and Go Test for Walking Assessment in Older Adults},
  journal = {Acta of Bioengineering and Biomechanics},
  year = {2026},
  volume = {28},
  number = {2},
  doi = {10.37190/abb/224360}
}
Kostenlos starten →