EUVIMEDEUVIMED entdecken
Crossref

Removal of antimonite by low-temperature Fe-modified biochar

Jiumei Long, Dongsheng Zhou

Asian Journal of Water, Environment and Pollution · 22.04.2026 · 23 (3) · 026050027

DOI: 10.36922/ajwep026050027 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Asian Journal of Water, Environment and Pollution, online erschienen am 22.04.2026. Verfasst von Jiumei Long und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-temperature biochar (BC) has been extensively studied for treating wastewater contaminated with antimonite (Sb(III)). In contrast, low-temperature BCs are more energy-efficient and eco-friendly, making them more promising for remediating contaminated environmental media; however, their performance and mechanisms for Sb(III) removal remain largely unexplored. To provide a theoretical basis for remediating antimony–contaminated natural environments, the present study investigated the Sb(III) removal performance and underlying mechanisms of two low-temperature (300 °C) BCs, namely ferric chloride (FeCl3) co-pyrolyzed BC (FB) and FeCl3-impregnated pristine BC (FBC), with pristine BC (PBC) as the control. The Sb(III) removal performance was evaluated using adsorption kinetic and isotherm models, and the mechanisms were elucidated via adsorption experiments across a pH range of 3–10. Results showed that the maximum adsorption capacities of PBC, FB, and FBC were 12.93, 9.01, and 14.57 mg·g−1, with FBC exhibiting superior Sb(III) removal performance. The kinetic model indicated that Sb(III) removal by FB and FBC was dominated by chemisorption. Characterization of the solid phases in the adsorption systems showed that functional groups were mainly responsible for Sb(III) adsorption/oxidation at pH 3, whereas co-oxidation of ferrous iron (Fe(II)) and Sb(III) was dominant at pH 10. Moreover, at an initial Sb(III) concentration of 5 mg·L−1, the residual aqueous Sb(III) in FBC-treated adsorption systems ranged from 0.015 to 0.036 mg·L−1 over the pH range of 3–10, indicating FBC’s high versatility in Sb(III) removal owing to its abundant functional groups and high Fe(II) content. Thus, FBC exhibits substantial potential to remediate Sb(III) contamination in environmental media across a typical environmental pH range of 3.0–10.0.

Zitieren

APA

Long, J., & Zhou, D. (2026). Removal of antimonite by low-temperature Fe-modified biochar. Asian Journal of Water, Environment and Pollution, 23(3), 026050027. https://doi.org/10.36922/ajwep026050027

Vancouver

Long J, Zhou D. Removal of antimonite by low-temperature Fe-modified biochar. Asian Journal of Water, Environment and Pollution. 2026;23(3):026050027. doi:10.36922/ajwep026050027

BibTeX
@article{Long2026,
  author = {Long, Jiumei and Zhou, Dongsheng},
  title = {Removal of antimonite by low-temperature Fe-modified biochar},
  journal = {Asian Journal of Water, Environment and Pollution},
  year = {2026},
  volume = {23},
  number = {3},
  pages = {026050027},
  doi = {10.36922/ajwep026050027}
}
Kostenlos starten →