EUVIMEDEUVIMED entdecken
Crossref

The influence of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implant

Anatoliy Potapchuk, Vasyl Almashi, Yevhen Onipko, Csaba Hegedűs

Wiadomości Lekarskie · 2024-03 · 77 (3) · 462-471

DOI: 10.36740/wlek202403114 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Wiadomości Lekarskie, 2024. Verfasst von Anatoliy Potapchuk und 3 weiteren Autor:innen. Beteiligte Einrichtung: UZHHOROD NATIONAL UNIVERSITY, UZHHOROD, UKRAINE. Hauptthemen laut MEDLINE: Immediate Dental Implant Loading. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To study the specifics of the impact of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implantation protocol. Materials and Methods: In the course of the study, orthopedic treatment was carried out for 55 patients aged 29 to 60 years. The following were performed: cone-beam computed tomography, software planning and intraoral scanning with an optical scanner, one-stage implantation protocol, assessment of implant stability with the Osstell ISQ device, microcirculation study in the peri-implant area using laser Doppler flowmetry (LDF).

Results

It was established that around loaded implants there is an increase in blood flow and vasomotor activity of the microcirculatory channel of the supporting tissues, an increase in the volume of bone tissue and an increase in torque, which is the optimal forecast for the acceleration of the pace of osseointegration.

Conclusions

The use of a splinting component during immediate intraoperative functional masticatory load accelerates the dynamics of bone tissue remodeling processes around the implant, which is an optimal prediction of osseointegration rates in various dental implantation protocols and is consistent with high values of the implant stability coefficient.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Immediate Dental Implant LoadingHumansMiddle AgedAdultMaleFemaleSplintsOsseointegrationDental ImplantsDental Implantation, EndosseousCone-Beam Computed Tomography

Stichwörter der Autor:innen

LDF (laser Doppler flowmetry)immediate intraoperative load,splinting componentone-stage dental implantation protocolstability Indicator

Substanzen

Dental Implants

Autor:innen und Institutionen

  • UZHHOROD NATIONAL UNIVERSITY, UZHHOROD, UKRAINE.
  • UNIVERSITY OF DEBRECEN, DEBRECEN, HUNGARY.

Zitieren

APA

Potapchuk, A., Almashi, V., Onipko, Y., & Hegedűs, C. (2024). The influence of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implant. Wiadomości Lekarskie, 77(3), 462-471. https://doi.org/10.36740/wlek202403114

Vancouver

Potapchuk A, Almashi V, Onipko Y, Hegedűs C. The influence of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implant. Wiadomości Lekarskie. 2024;77(3):462-471. doi:10.36740/wlek202403114

BibTeX
@article{Potapchuk2024,
  author = {Potapchuk, Anatoliy and Almashi, Vasyl and Onipko, Yevhen and Hegedűs, Csaba},
  title = {The influence of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implant},
  journal = {Wiadomości Lekarskie},
  year = {2024},
  volume = {77},
  number = {3},
  pages = {462--471},
  doi = {10.36740/wlek202403114}
}
Kostenlos starten →