Übersichtsarbeit in der Zeitschrift Wiadomości Lekarskie, online erschienen am 30.04.2026. Verfasst von Krzysztof Jakimow und 2 weiteren Autor:innen. Beteiligte Einrichtung: DOCTORAL SCHOOL, INSTITUTE OF MEDICAL SCIENCES, UNIVERSITY OF OPOLE, OPOLE, POLAND; CLINICAL DEPARTMENT OF DIAGNOSTIC IMAGING, UNIVERSITY HOSPITAL, I…. Hauptthemen laut MEDLINE: Endovascular Aneurysm Repair, Aortic Aneurysm, Abdominal, Endovascular Procedures, Endoleak.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Abdominal aortic aneurysm is a life-threatening condition with mortality rates exceeding 80% following rupture. Risk factors for aneurysm development include advanced age, tobacco smoking history, male sex, family history, cardiovascular disease, and hypertension. Two primary treatment modalities exist: open surgical repair and endovascular aortic repair. The latter aims to exclude the aneurysmal sac from circulation through endograft placement. Given the lower complication rates associated with endovascular aortic repair compared with open surgery, the endovascular approach is the preferred treatment in selected patients. Endoleaks are the most common complication after endovascular aortic repair and necessitate lifelong surveillance. This review aims to present diagnostic modalities suitable for monitoring patients after endovascular aortic repair. Materials and methods: A literature search was conducted across electronic databases from January 2024 to May 2025 using a combination of keywords and Boolean operators.

Discussion

While computed tomography angiography remains the reference standard for monitoring after endovascular aortic repair, with 92% sensitivity for endoleak detection, magnetic resonance imaging and ultrasonography offer viable alternatives that eliminate radiation exposure and may reduce contrast agent requirements. Magnetic resonance imaging detects twice as many endoleaks as computed tomography angiography, whereas contrast-enhanced duplex ultrasonography achieves 98% sensitivity and 88% specificity.

Conclusion

Treatment of abdominal aorta aneurysm with endovascular aortic repair offers a significant opportunity for a carefully selected patient population. The selection of surveillance modalities should be tailored to individual patient characteristics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endovascular Aneurysm RepairAortic Aneurysm, AbdominalEndovascular ProceduresEndoleakPostoperative ComplicationsHumansComputed Tomography AngiographyMagnetic Resonance ImagingUltrasonographyContrast Media

Stichwörter der Autor:innen

computed tomography angiographycontrast mediaendovascular aortic repairmagnetic resonance imagingultrasonography

Substanzen

Contrast Media

Autor:innen und Institutionen

  • DOCTORAL SCHOOL, INSTITUTE OF MEDICAL SCIENCES, UNIVERSITY OF OPOLE, OPOLE, POLAND; CLINICAL DEPARTMENT OF DIAGNOSTIC IMAGING, UNIVERSITY HOSPITAL, INSTITUTE OF MEDICAL SCIENCES, UNIVERSITY OF OPOLE, OPOLE, POLAND.
  • DOCTORAL SCHOOL, MEDICAL UNIVERSITY OF SILESIA, KATOWICE, POLAND.
  • CLINICAL DEPARTMENT OF DIAGNOSTIC IMAGING, UNIVERSITY HOSPITAL, INSTITUTE OF MEDICAL SCIENCES, UNIVERSITY OF OPOLE, OPOLE, POLAND.

Zitieren

APA

Jakimow, K., Ciesielka, J., & Sznajder, K. (2026). Radiological Follow-Up After Endovascular Aortic Repair – Review of Surveillance Modalities. Wiadomości Lekarskie, 855-862. https://doi.org/10.36740/wlek/218764

Vancouver

Jakimow K, Ciesielka J, Sznajder K. Radiological Follow-Up After Endovascular Aortic Repair – Review of Surveillance Modalities. Wiadomości Lekarskie. 2026:855-862. doi:10.36740/wlek/218764

BibTeX
@article{Jakimow2026,
  author = {Jakimow, Krzysztof and Ciesielka, Jakub and Sznajder, Katarzyna},
  title = {Radiological Follow-Up After Endovascular Aortic Repair – Review of Surveillance Modalities},
  journal = {Wiadomości Lekarskie},
  year = {2026},
  number = {4},
  pages = {855--862},
  doi = {10.36740/wlek/218764}
}