ANALISIS KOMPARATIF KUALITAS AIR IPAL SUWUNG DAN WADUK TUKAD BADUNG SEBAGAI AIR HIGIENE SANITASI
Jurnal Ecocentrism · 10.11.2026 · 6 (2) · 95-104
DOI: 10.36733/jeco.v6i2.14669 ↗Kurz gefasst
Fachartikel in der Zeitschrift Jurnal Ecocentrism, online erschienen am 10.11.2026. Verfasst von Anak Agung Ratu Ritaka Wangsa und 3 weiteren Autor:innen.
Abstract (Originalsprache)
The threat of water deficit in South Bali drives the urgency of utilizing non-conventional water sources such as treated wastewater effluent and urban surface water. This study aims to analyze and compare the water quality of Suwung WWTP effluent and Tukad Badung Reservoir water as potential raw water sources for hygiene and sanitation purposes based on the Environmental Health Quality Standards of Permenkes RI No. 2/2023. Physical, chemical, and bacteriological parameters were tested at the Quantum Sarana Medik Laboratory, Denpasar. Results showed that the water quality of Tukad Badung Reservoir generally aligns more closely with standard limits than Suwung WWTP effluent. Turbidity in Suwung WWTP effluent (90 NTU) exceeded the maximum allowable threshold (25 NTU). Bacteriologically, both water sources exhibited severe contamination, with Total Coliform (>2,400 MPN/100 mL) and Escherichia coli (460 MPN/100 mL in the reservoir and 920 MPN/100 mL in the WWTP) exceeding safe limits (50 CFU/100 mL for Coliform and 0 CFU/100 mL for E. coli). In conclusion, both water sources are not recommended for direct use without tertiary treatment such as rapid filtration, activated carbon adsorption, ultrafiltration, and advanced disinfection (Ozone/UV).
Zitieren
APA
Wangsa, A. A. R. R., Praganingrum, T. I., Suryatmaja, I. B., & Pradnyadari, N. L. M. A. M. (2026). ANALISIS KOMPARATIF KUALITAS AIR IPAL SUWUNG DAN WADUK TUKAD BADUNG SEBAGAI AIR HIGIENE SANITASI. Jurnal Ecocentrism, 6(2), 95-104. https://doi.org/10.36733/jeco.v6i2.14669
Vancouver
Wangsa AARR, Praganingrum TI, Suryatmaja IB, Pradnyadari NLMAM. ANALISIS KOMPARATIF KUALITAS AIR IPAL SUWUNG DAN WADUK TUKAD BADUNG SEBAGAI AIR HIGIENE SANITASI. Jurnal Ecocentrism. 2026;6(2):95-104. doi:10.36733/jeco.v6i2.14669
BibTeX
@article{Wangsa2026,
author = {Wangsa, Anak Agung Ratu Ritaka and Praganingrum, Tjokorda Istri and Suryatmaja, Ida Bagus and Pradnyadari, Ni Luh Made Ayu Mirayani},
title = {ANALISIS KOMPARATIF KUALITAS AIR IPAL SUWUNG DAN WADUK TUKAD BADUNG SEBAGAI AIR HIGIENE SANITASI},
journal = {Jurnal Ecocentrism},
year = {2026},
volume = {6},
number = {2},
pages = {95--104},
doi = {10.36733/jeco.v6i2.14669}
}