EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

ANALISIS KUALITAS AIR MINUM DAN KANDUNGAN LOGAM BERAT TIMBAL (Pb) PADA DEPOT AIR MINUM ISI ULANG (DAMIU) DI KOTA PALANGKA RAYA-KALIMATAN TENGAH

Dwi Hermayantiningsih, Muh. Supwatul Hakim, Tety Wahyuningsih Manurung

Jurnal Crystal : Publikasi Penelitian Kimia dan Terapannya · 31.03.2026 · 8 (1) · 7-14

DOI: 10.36526/jc.v8i1.5945 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Jurnal Crystal : Publikasi Penelitian Kimia dan Terapannya, online erschienen am 31.03.2026. Verfasst von Dwi Hermayantiningsih und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An analysis of drinking water quality, including physical parameters such as TDS (Total Dissolved Solids), color, odor, and taste, as well as chemical parameters such as pH and lead ion content in refillable drinking water depots in Palangka Raya City, has been conducted. Drinking water requirements must comply with the Regulation of the Minister of Health of the Republic of Indonesia Number 2 of 2023 concerning the Implementation of Government Regulation Number 66 of 2014 regarding Environmental Health. The method throughout this investigation is laboratory experiment. Samples of refillable drinking water were obtained using a random sampling method at 9 different locations in Jekan Raya District. Based on the analysis of physical parameters including TDS, color, odor, and taste, the drinking water sample still meets drinking water quality standards. The results of pH measurements at 7 out of 9 sampling points showed that the pH values of 6.5-8.5 did not meet the quality standards. Analysis of lead (Pb) levels based on AAS showed that the Pb content in 9 samples was below the maximum permissible standard of 0.01 mg/L.

Zitieren

APA

Hermayantiningsih, D., Hakim, M. S., & Manurung, T. W. (2026). ANALISIS KUALITAS AIR MINUM DAN KANDUNGAN LOGAM BERAT TIMBAL (Pb) PADA DEPOT AIR MINUM ISI ULANG (DAMIU) DI KOTA PALANGKA RAYA-KALIMATAN TENGAH. Jurnal Crystal : Publikasi Penelitian Kimia dan Terapannya, 8(1), 7-14. https://doi.org/10.36526/jc.v8i1.5945

Vancouver

Hermayantiningsih D, Hakim MS, Manurung TW. ANALISIS KUALITAS AIR MINUM DAN KANDUNGAN LOGAM BERAT TIMBAL (Pb) PADA DEPOT AIR MINUM ISI ULANG (DAMIU) DI KOTA PALANGKA RAYA-KALIMATAN TENGAH. Jurnal Crystal : Publikasi Penelitian Kimia dan Terapannya. 2026;8(1):7-14. doi:10.36526/jc.v8i1.5945

BibTeX
@article{Hermayantiningsih2026,
  author = {Hermayantiningsih, Dwi and Hakim, Muh. Supwatul and Manurung, Tety Wahyuningsih},
  title = {ANALISIS KUALITAS AIR MINUM DAN KANDUNGAN LOGAM BERAT TIMBAL (Pb) PADA DEPOT AIR MINUM ISI ULANG (DAMIU) DI KOTA PALANGKA RAYA-KALIMATAN TENGAH},
  journal = {Jurnal Crystal : Publikasi Penelitian Kimia dan Terapannya},
  year = {2026},
  volume = {8},
  number = {1},
  pages = {7--14},
  doi = {10.36526/jc.v8i1.5945}
}
Kostenlos starten →