EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

The bacterial profile and sensitivity patterns of isolates from medical equipment and surfaces in the Children’s emergency room of a Nigerian hospital

Ikenna Kingsley Ndu, Isaac Nwabueze Asinobi, Uchenna Ekwochi, Obinna Chukwuebuka Nduagubam, Ogechukwu Francesca Amadi, Ifeyinwa Bernadette Okeke, Chukwunonso Chigozie Iheji, Ngozi Nancy Onu

Medical Science and Discovery · 12.09.2019 · 6 (9) · 192-197

DOI: 10.36472/msd.v6i9.291 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Science and Discovery, online erschienen am 12.09.2019. Verfasst von Ikenna Kingsley Ndu und 7 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Nosocomial infections are those acquired in hospitals or healthcare service units that first appear 48 hours or more after admission or within 30 days after discharge following in-patient care. Knowledge of the bacterial profile and sensitivity patterns of any hospital environment is a key factor in infection control and good antibiotic stewardship. Material and Methods: This hospital-based cross-sectional study was conducted in the Children’s Emergency Room (CHER) of Enugu State University Teaching Hospital, Enugu, Nigeria. Samples for culture were collected from equipment and hospital surfaces. Antimicrobial susceptibility testing was determined for each isolate by the Agar diffusion method using Standard Nutrient Agar 1 discs.

Results

Bacterial growth was observed in 83 (70.3%) specimens. Staphylococcus aureus (53.4%) was the most common isolate cultured followed by Coagulase-negative Staphylococcus (18.8%), then Escherichia coli (13.9%). Among Staphylococcus aureus isolates, 25.9% were MRSA. Ampicillin resistance of the gram negatives was high. All the Gram-negative isolates were susceptible to Ciprofloxacin and Ceftriaxone.

Conclusion

Staphylococcus aureus, Coagulase-negative Staphylococcus, and Escherichia coli were the commonest isolates. More efforts are needed to ensure improved hygiene standards in order to reduce the burden of nosocomial infections.

Zitieren

APA

Ndu, I. K., Asinobi, I. N., Ekwochi, U., Nduagubam, O. C., Amadi, O. F., Okeke, I. B., Iheji, C. C., & Onu, N. N. (2019). The bacterial profile and sensitivity patterns of isolates from medical equipment and surfaces in the Children’s emergency room of a Nigerian hospital. Medical Science and Discovery, 6(9), 192-197. https://doi.org/10.36472/msd.v6i9.291

Vancouver

Ndu IK, Asinobi IN, Ekwochi U, Nduagubam OC, Amadi OF, Okeke IB, et al. The bacterial profile and sensitivity patterns of isolates from medical equipment and surfaces in the Children’s emergency room of a Nigerian hospital. Medical Science and Discovery. 2019;6(9):192-197. doi:10.36472/msd.v6i9.291

BibTeX
@article{Ndu2019,
  author = {Ndu, Ikenna Kingsley and Asinobi, Isaac Nwabueze and Ekwochi, Uchenna and Nduagubam, Obinna Chukwuebuka and Amadi, Ogechukwu Francesca and Okeke, Ifeyinwa Bernadette and Iheji, Chukwunonso Chigozie and Onu, Ngozi Nancy},
  title = {The bacterial profile and sensitivity patterns of isolates from medical equipment and surfaces in the Children’s emergency room of a Nigerian hospital},
  journal = {Medical Science and Discovery},
  year = {2019},
  volume = {6},
  number = {9},
  pages = {192--197},
  doi = {10.36472/msd.v6i9.291}
}
Kostenlos starten →