Improving retention of removable orthodontic appliances by accounting for hard-palate mucosal compliance
Endodontics Today · 21.10.2026
DOI: 10.36377/et-0244 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endodontics Today, online erschienen am 21.10.2026. Verfasst von I. D. Ushnitsky und 1 weiteren Autor:innen. Die Arbeit nennt 10 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION. Retention of removable orthodontic appliances remains a clinical challenge. An individualized approach to compression and decompression zones of the hard-palate mucosa may improve the fit and functional retention of the appliance. PURPOSE. To develop a method for improving retention of removable orthodontic appliances that accounts for individual compression and decompression areas of the hard-palate mucosa, and to evaluate its clinical effectiveness. MATERIALS AND METHODS. The study included 143 children aged 6–10 years, allocated to a main group ( n = 76) and a control group ( n = 67). The method combined contrast-enhanced CBCT, assessment of individual mucosal anatomy, virtual 3D modeling, and fabrication of a customized appliance. Retention force was measured with an orthodontic dynamometer; dislodgement episodes were recorded over 6 months. Student’s t-test was used, with p < 0.05 considered significant. RESULTS. Mean retention force was 8.25 ± 0.07 N in the main group and 6.29 ± 0.08 N in controls ( p < 0.05). Dislodgement episodes per patient over 6 months averaged 0.59 ± 0.12 and 1.37 ± 0.09, respectively ( p < 0.05). Clinical and cephalometric changes were also evaluated. CONCLUSION. The individualized compression/decompression approach was associated with higher retention force and fewer dislodgement episodes over 6 months. The findings support its potential to improve functional retention of removable orthodontic appliances.
Zitieren
APA
Ushnitsky, I. D., & Piksaykina-Grigorieva, K. G. (2026). Improving retention of removable orthodontic appliances by accounting for hard-palate mucosal compliance. Endodontics Today. https://doi.org/10.36377/et-0244
Vancouver
Ushnitsky ID, Piksaykina-Grigorieva KG. Improving retention of removable orthodontic appliances by accounting for hard-palate mucosal compliance. Endodontics Today. 2026. doi:10.36377/et-0244
BibTeX
@article{Ushnitsky2026,
author = {Ushnitsky, I. D. and Piksaykina-Grigorieva, K. G.},
title = {Improving retention of removable orthodontic appliances by accounting for hard-palate mucosal compliance},
journal = {Endodontics Today},
year = {2026},
doi = {10.36377/et-0244}
}
EUVIMED