EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Effect of Different Soft Contact Lenses Tear Film Stability in Myopes

Sadia Saddiqi, Hadia Asif, Tayyeba Akram, Summan Razzaq, Bisma Arshad

Pakistan Journal of Ophthalmology · 31.03.2026 · 42 (2)

DOI: 10.36351/pjo.v42i2.2214 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pakistan Journal of Ophthalmology, online erschienen am 31.03.2026. Verfasst von Sadia Saddiqi und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess the influence of soft contact lens wear on tear film stability in myopes. Study Design: Quasi experimental study. Place and Duration of Study: Social Security Hospital, Multan Road, Lahore, from February 2025 to May 2025.

Methods

Myopic participants with no prior experience of wearing contact lenses were chosen and were divided into two equal groups based on the type of lens: soft hydrogel; and silicone hydrogel. Patients with dry eyes, refractive errors other than myopia, or using systemic medications were excluded from the study. Tear film stability was evaluated with Tear Break-Up Time (TBUT), conducted before and after one month of lens wear. Data analysis was performed using SPSS, Version 27. A p-value < 0.05 was considered statistically significant.

Results

The study enrolled 90 myopic patients. For TBUT, soft hydrogel lenses showed a minor but significant reduction from 11.99s to 11.88s (Mean difference = -0.11s, p < 0.050), while silicone hydrogel lenses exhibited a significant improvement from 11.71s to 13.28s (Mean difference = +1.57s, p < 0.001). Independent t-test revealed that silicone hydrogel lenses had significantly greater positive changes in TBUT compared to soft hydrogels, indicating improved tear film stability after one month of lens wear.

Conclusion

This study shows that wearing soft contact lenses impacts tear film stability in myopic patients, however a positive or negative response depends on type of lens material worn.

Zitieren

APA

Saddiqi, S., Asif, H., Akram, T., Razzaq, S., & Arshad, B. (2026). Effect of Different Soft Contact Lenses Tear Film Stability in Myopes. Pakistan Journal of Ophthalmology, 42(2). https://doi.org/10.36351/pjo.v42i2.2214

Vancouver

Saddiqi S, Asif H, Akram T, Razzaq S, Arshad B. Effect of Different Soft Contact Lenses Tear Film Stability in Myopes. Pakistan Journal of Ophthalmology. 2026;42(2). doi:10.36351/pjo.v42i2.2214

BibTeX
@article{Saddiqi2026,
  author = {Saddiqi, Sadia and Asif, Hadia and Akram, Tayyeba and Razzaq, Summan and Arshad, Bisma},
  title = {Effect of Different Soft Contact Lenses Tear Film Stability in Myopes},
  journal = {Pakistan Journal of Ophthalmology},
  year = {2026},
  volume = {42},
  number = {2},
  doi = {10.36351/pjo.v42i2.2214}
}
Kostenlos starten →