EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Detection of highly pathogenic orthopoxviruses (Poxviridae: Chordopoxvirinae: Orthopoxvirus) by dot immunoassay in a high-containment biological safety laboratory

A V Ersh iD, A G Poltavchenko iD, N D Ushkalenko iD, P V Filatov iD, K A Titova iD, D A Odnoshevsky iD, A A Sergeev iD, A A Sergeev iD

Problems of Virology · 2025

DOI: 10.36233/0507-4088-332 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Problems of Virology, 2025. Verfasst von A V Ersh und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Scientific Center of Virology and Biotechnology «Vector». Hauptthemen laut MEDLINE: Orthopoxvirus, Immunoassay, Laboratories, Containment of Biohazards. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Highly pathogenic for humans orthopoxviruses (OPV) – Variola virus (VARV) and Monkeypox virus (MPXV) can cause systemic diseases characterized by high contagiousness and often leading to death. In previous publications (https://doi.org/10.3390/v14112580), we reported on the development of a sensitive, rapid and easy-to-use immunochemical test potentially suitable for use in the infection foci and in laboratory conditions with a high level of biosecurity. The prototype of the diagnostic kit was tested on non-pathogenic and low-pathogenic for humans OPV and specifically detected them with a sensitivity within the range of 103 to 104 PFU/mL. The aim of this work was to evaluate the sensitivity of this assay in detecting highly pathogenic for humans MPXV and VARV, as well as the applicability of the assay in a laboratory with a high level of biosafety (BSL-4). Materials and methods. The efficiency of virus detection in cryolysates of CV-1 cell culture samples infected with VARV and MPXV was assessed using a one-step dot immunoassay method in a laboratory with biosafety level BSL-4.

Results

It was shown that the one-step dot assay allows detection of MPXV at a concentration of 2.5 × 103 PFU/mL, and VARV at a concentration of 1.0 × 104 PFU/mL. It was noted that vapors from disinfectants (hydrogen peroxide/formaldehyde) applied in biosafety cabinet decontamination may interfere with assay performance and affect result interpretation.

Conclusion

The one-step dot immunoassay can be performed in a BSL-4 laboratory. When limiting the contact of the detecting system with formaldehyde vapors, the sensitivity of the test for detection of VARV and MPXV falls within the previously declared range of 103–104 PFU/mL.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OrthopoxvirusImmunoassayLaboratoriesContainment of BiohazardsChlorocebus aethiopsCell LineAnimalsVariola virusMonkeypox virusSensitivity and Specificity

Stichwörter der Autor:innen

detectiondot immunoassaymonkeypox virussmallpox virus

Autor:innen und Institutionen

  • State Scientific Center of Virology and Biotechnology «Vector».

ORCID-Profile: A V Ersh, A G Poltavchenko, N D Ushkalenko, P V Filatov, K A Titova, D A Odnoshevsky, A A Sergeev, A A Sergeev

Zitieren

APA

Ersh, A. V., Poltavchenko, A. G., Ushkalenko, N. D., Filatov, P. V., Titova, K. A., Odnoshevsky, D. A., Sergeev, A. A., & Sergeev, A. A. (2025). Detection of highly pathogenic orthopoxviruses (Poxviridae: Chordopoxvirinae: Orthopoxvirus) by dot immunoassay in a high-containment biological safety laboratory. Problems of Virology. https://doi.org/10.36233/0507-4088-332

Vancouver

Ersh AV, Poltavchenko AG, Ushkalenko ND, Filatov PV, Titova KA, Odnoshevsky DA, et al. Detection of highly pathogenic orthopoxviruses (Poxviridae: Chordopoxvirinae: Orthopoxvirus) by dot immunoassay in a high-containment biological safety laboratory. Problems of Virology. 2025. doi:10.36233/0507-4088-332

BibTeX
@article{Ersh2025,
  author = {Ersh, A V and Poltavchenko, A G and Ushkalenko, N D and Filatov, P V and Titova, K A and Odnoshevsky, D A and Sergeev, A A and Sergeev, A A},
  title = {Detection of highly pathogenic orthopoxviruses (Poxviridae: Chordopoxvirinae: Orthopoxvirus) by dot immunoassay in a high-containment biological safety laboratory},
  journal = {Problems of Virology},
  year = {2025},
  doi = {10.36233/0507-4088-332}
}
Kostenlos starten →