EUVIMEDEUVIMED entdecken
Open Access

Cutoffs for serum mold-specific IgG levels for hypersensitivity pneumonitis: a diagnostic test accuracy study of 219 subjects.

Sahajal Dhooria, Ritesh Agarwal, Inderpaul Singh Sehgal, Valliappan Muthu, Kuruswamy Thurai Prasad, Shivaprakash M Rudramurthy, Nalini Gupta, Amanjit Bal, Mani Singh Meho, Mandeep Kaur, Mandeep Garg, Ashutosh Nath Aggarwal

Sarcoidosis vasculitis and diffuse lung diseases · 22.06.2026 · 43 (2) · 18031-18031

DOI: 10.36141/svdld.2026.18031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sarcoidosis vasculitis and diffuse lung diseases, erschienen am 22.06.2026. Verfasst von Sahajal Dhooria und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pulmonary Medicine, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: American Thoracic Society guidelines suggest serum specific IgG (sIgG) testing targeting potential antigens associated with hypersensitivity pneumonitis (HP). The diagnostic cutoffs of mold-sIgGs remain undefined and their performance based on pre- and post-test probabilities remain untested. METHODS: We conducted a diagnostic test accuracy study using a case-control design. We enrolled subjects with HP (cases), other interstitial lung diseases (ILDs, diseased controls), and healthy controls with/without mold exposure. We measured sIgG against Aspergillus fumigatus, Penicillium chrysogenum, Cladosporium herbarum, and Micropolyspora faeni using an automated, fluorescent enzyme immunoassay. Cutoffs were derived from the 95th percentile values among non-exposed healthy controls for individual sIgGs and Youden's J-statistic for pooled sIgG (sum of four levels). We evaluated the performance characteristics of sIgG levels for HP diagnosis among subjects with ILDs. RESULTS: We included 219 subjects (mean age, 51.4 years; 50.2% women): 105 HP, 64 non-HP ILDs, and 50 healthy controls (25 non-exposed, 25 exposed). Cutoffs (mgA/L) were 33, 22, 34, 8, and 53, for A. fumigatus, P. chrysogenum, C. herbarum, M. faeni, and pooled sIgG levels, respectively. The 4-mold panel (positive if any sIgG exceeded cutoff) showed 57.1% sensitivity and 78.1% specificity for HP diagnosis among ILD subjects. The pooled sIgG test (positive likelihood ratio, 3.29; negative likelihood ratio, 0.51) shifted post-test probability of HP diagnosis from 44% (for a negative test) to 84% (for a positive test). CONCLUSION: Mold-specific IgGs, when used at our proposed cutoffs, significantly alter post-test diagnostic probabilities; thus, can be used as an adjunct in multi-component HP diagnosis.

Schlagwörter

hypersensitivity pneumonitisdiagnostic thresholdsAspergillus fumigatusPenicillium chrysogenumCladosporium herbarumMicropolyspora faeniinterstitial lung diseaseserological diagnosisdiagnostic accuracylikelihood ratios

Autor:innen und Institutionen

  • Department of Pulmonary Medicine, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.
  • Department of Medical Microbiology, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.
  • Department of Cytology and Gynecologic Pathology, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.
  • Department of Histopathology, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.
  • Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.

Zitieren

APA

Dhooria, S., Agarwal, R., Sehgal, I. S., Muthu, V., Prasad, K. T., Rudramurthy, S. M., Gupta, N., Bal, A., Meho, M. S., Kaur, M., Garg, M., & Aggarwal, A. N. (2026). Cutoffs for serum mold-specific IgG levels for hypersensitivity pneumonitis: a diagnostic test accuracy study of 219 subjects. Sarcoidosis vasculitis and diffuse lung diseases, 43(2), 18031-18031. https://doi.org/10.36141/svdld.2026.18031

Vancouver

Dhooria S, Agarwal R, Sehgal IS, Muthu V, Prasad KT, Rudramurthy SM, et al. Cutoffs for serum mold-specific IgG levels for hypersensitivity pneumonitis: a diagnostic test accuracy study of 219 subjects. Sarcoidosis vasculitis and diffuse lung diseases. 2026;43(2):18031-18031. doi:10.36141/svdld.2026.18031

BibTeX
@article{Dhooria2026,
  author = {Dhooria, Sahajal and Agarwal, Ritesh and Sehgal, Inderpaul Singh and Muthu, Valliappan and Prasad, Kuruswamy Thurai and Rudramurthy, Shivaprakash M and Gupta, Nalini and Bal, Amanjit and Meho, Mani Singh and Kaur, Mandeep and Garg, Mandeep and Aggarwal, Ashutosh Nath},
  title = {Cutoffs for serum mold-specific IgG levels for hypersensitivity pneumonitis: a diagnostic test accuracy study of 219 subjects},
  journal = {Sarcoidosis vasculitis and diffuse lung diseases},
  year = {2026},
  volume = {43},
  number = {2},
  pages = {18031--18031},
  doi = {10.36141/svdld.2026.18031}
}
Kostenlos starten →