Spo2 Analysis on Development of IoT-Based Lung Function and Spo2 Measuring Device
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics · 2024
DOI: 10.35882/dx15cf29 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics, 2024. Verfasst von Nadya Shavira und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).
Abstract (Originalsprache)
Pulmonary dysfunction is a widespread issue, particularly in developing nations. It encompasses restrictive, obstructive, and mixed pulmonary function disorders that lead to a decrease in vital lung capacity, an increase in functional residual capacity, and a decline in blood oxygen concentration and saturation. This study aims to combine oximetry and spirometry into a single device, using the Internet of Things (IoT) technology to display results via a smartphone app. The focus is on analyzing oxygen saturation, with normal levels ranging from 96% to 100% in adults, alongside a heart rate of 60-100 beats per minute. The MAX30102 sensor measures oxygen saturation, and the Arduino Pro Mini and D1 Mini ESP32 microcontrollers process data. The Android-based app, developed using Kodular platform, integrates a MySQL database and connects to the device module via Wi-Fi. Ten respondents underwent five measurements, revealing an average error of ±0.88% for oxygen saturation (SpO2) and ±2.82% for heart rate measurements. The average data loss rate during transmission was ±0.66% for SpO2 and ±0.89% for heart rate. These findings highlight existing errors in the module. The research aims to facilitate remote health monitoring for healthcare professionals, improving accessibility and healthcare provision
Zitieren
APA
Shavira, N., Ariswati, H. G., & Hamzah, T. (2024). Spo2 Analysis on Development of IoT-Based Lung Function and Spo2 Measuring Device. Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics. https://doi.org/10.35882/dx15cf29
Vancouver
Shavira N, Ariswati HG, Hamzah T. Spo2 Analysis on Development of IoT-Based Lung Function and Spo2 Measuring Device. Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics. 2024. doi:10.35882/dx15cf29
BibTeX
@article{Shavira2024,
author = {Shavira, Nadya and Ariswati, Her Gumiwang and Hamzah, Torib},
title = {Spo2 Analysis on Development of IoT-Based Lung Function and Spo2 Measuring Device},
journal = {Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics},
year = {2024},
doi = {10.35882/dx15cf29}
}
EUVIMED