EUVIMEDEUVIMED entdecken
Crossref

Monitoring of Estrone from Hospital Wastewater and its Removal by Photocatalytic Membrane Reactor

Nicha Karnjanamit, Chongdee Thammakhet-Buranachai, Panitan Jutaporn, Watsa Khongnakorn

Applied Environmental Research · 25.06.2024

DOI: 10.35762/aer.2024023 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Environmental Research, online erschienen am 25.06.2024. Verfasst von Nicha Karnjanamit und 3 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Steroid hormones, classified as endocrine-disrupting compounds (EDCs), pose significant environmental and health concerns due to their persistence and potential adverse effects. This study investigates the presence of estrone (E1) in hospital wastewater and the efficiency of E1 removal through a photocatalytic membrane reactor (PMR). Wastewater samples were collected from two hospitals with different wastewater treatment processes. The concentration of E1 was analyzed using a combination of solid phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The PMR experimental setup involved a polyvinylidene fluoride (PVDF) membrane incorporated with 1 wt% titanium dioxide (PVDF/TiO2). The PMR performance was evaluated with and without UVC radiation. The membranes were characterized for their water contact angle (WCA) and surface morphology. The maximum concentration of E1 in the hospital wastewater was 2.46 ± 1.90 ng L-1. The PMR, operated for 180 min, demonstrated that PVDF/TiO2 (UV) exhibited the highest E1 removal efficiency (96.7 ± 1.4%). This superior performance was attributed to the synergistic effect of PVDF/TiO2 membrane filtration combined with UV irradiation, enhancing the removal capacity. The removal of E1 in the PVDF/TiO2 membrane (36.5 ± 2.7%) surpassed that of the PVDF membrane (32.6 ± 7.8%). The kinetics analysis indicated that the degradation of E1 followed pseudo first-order kinetics. These findings underscore the potential of PMR technology, specifically employing PVDF/TiO2 membranes with UV irradiation, for efficient removal of E1 from hospital wastewater, offering insights for future applications in mitigating micropollutant release into the environment.

Zitieren

APA

Karnjanamit, N., Thammakhet-Buranachai, C., Jutaporn, P., & Khongnakorn, W. (2024). Monitoring of Estrone from Hospital Wastewater and its Removal by Photocatalytic Membrane Reactor. Applied Environmental Research. https://doi.org/10.35762/aer.2024023

Vancouver

Karnjanamit N, Thammakhet-Buranachai C, Jutaporn P, Khongnakorn W. Monitoring of Estrone from Hospital Wastewater and its Removal by Photocatalytic Membrane Reactor. Applied Environmental Research. 2024. doi:10.35762/aer.2024023

BibTeX
@article{Karnjanamit2024,
  author = {Karnjanamit, Nicha and Thammakhet-Buranachai, Chongdee and Jutaporn, Panitan and Khongnakorn, Watsa},
  title = {Monitoring of Estrone from Hospital Wastewater and its Removal by Photocatalytic Membrane Reactor},
  journal = {Applied Environmental Research},
  year = {2024},
  doi = {10.35762/aer.2024023}
}
Kostenlos starten →