Bacteriological Quality Analysis of Regional Water Utility (PDAM) Water Based on the Padang Panjang City Distribution System(A Case Study in Koto Katiak)
Nusantara Journal of Public Health · 31.03.2026 · 1 (1) · 84-94
DOI: 10.35730/8nj9bw82 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nusantara Journal of Public Health, online erschienen am 31.03.2026. Verfasst von Nurdin und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).
Abstract (Originalsprache)
Background
Water quality impacts human, plant, and animal life, as all rely on water for survival. Within the service area of the Koto Katiak Community Health Center (Puskesmas), the most common source of clean water is the Regional Water Utility Company (PDAM), serving 1,407 households (60.67%). Bacteriological testing conducted by the Bukittinggi City Health Laboratory in 2013 revealed that none of the ten samples analyzed met the required standards. This study aims to determine the difference in the bacteriological quality of PDAM water before and after distribution to the community.
Method
The study employed a quasi-experimental method with a pre-test/post-test time-series design. It was conducted within the service area of the Koto Katiak Community Health Center (Puskesmas) in Padang Panjang City. Data were processed and analyzed using a computerized paired-sample t-test.
Results
Univariate analysis revealed that the average bacteriological water quality was 99 colonies/100 ml during normal weather and 1,425 colonies/100 ml after rainfall prior to PDAM treatment; 251 colonies/100 ml and 157 colonies/100 ml after PDAM treatment; and 101.65 colonies/100 ml and 36.63 colonies/100 ml after distribution to the community. Bivariate analysis showed a difference in bacteriological water quality before and after PDAM treatment following rainfall (p = 0.043). There was a difference in bacteriological water quality prior to PDAM treatment between normal weather and rainy weather (p = 0.025). No difference was found in bacteriological water quality between the post-treatment stage and the post-distribution stage during normal weather (p = 0.153) or rainy weather (p = 0.342). A difference existed in the bacteriological quality of raw PDAM water between normal weather and rainy weather (p = 0.025).
Conclusion
It is concluded that there are differences in the bacteriological quality of water before and after PDAM treatment during rainy weather, as well as differences in the bacteriological quality of raw water between normal and rainy weather conditions. It is recommended that the PDAM agency strive to ensure a supply of raw water that is safe and protected from contamination, improve the quality of protection basins, and monitor the piping network for factors that could compromise water quality.
Zitieren
APA
Nurdin, Yanti, C. A., & Afriandi, D. (2026). Bacteriological Quality Analysis of Regional Water Utility (PDAM) Water Based on the Padang Panjang City Distribution System(A Case Study in Koto Katiak). Nusantara Journal of Public Health, 1(1), 84-94. https://doi.org/10.35730/8nj9bw82
Vancouver
Nurdin, Yanti CA, Afriandi D. Bacteriological Quality Analysis of Regional Water Utility (PDAM) Water Based on the Padang Panjang City Distribution System(A Case Study in Koto Katiak). Nusantara Journal of Public Health. 2026;1(1):84-94. doi:10.35730/8nj9bw82
BibTeX
@article{Nurdin2026,
author = {Nurdin and Yanti, Cici Apriza and Afriandi, Dodi},
title = {Bacteriological Quality Analysis of Regional Water Utility (PDAM) Water Based on the Padang Panjang City Distribution System(A Case Study in Koto Katiak)},
journal = {Nusantara Journal of Public Health},
year = {2026},
volume = {1},
number = {1},
pages = {84--94},
doi = {10.35730/8nj9bw82}
}