Application of IR-spectrometry and independent component analisys for the quantitative determination of ademethionine in tablets
Aspirantskiy Vestnik Povolzhiya · 08.05.2026 · 26 (2) · 49-57
DOI: 10.35693/avp698869 ↗Kurz gefasst
Fachartikel in der Zeitschrift Aspirantskiy Vestnik Povolzhiya, online erschienen am 08.05.2026. Verfasst von Irina V. Kachalkina und 2 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aim: evaluation of the metrological characteristics of the method for the quantitative determination of ademethionine in tablets by IR-spectrometry in the attenuated total internal reflection mode using the independent component analysis. Material and methods. IR-spectra were recorded using an Agilent Cary 630 FTIR spectrometer in the attenuated total internal reflection mode (crystal - diamond) in the wavenumber range from 4000 to 650 cm-¹ with a resolution of 4 cm-¹. The processing of IR-spectra was performed using Agilent Microlab Expert 1.0.0.7 software (IR-spectra registration, ATR correction) and KNIME 5.3.2 with pre-installed Python 3.9.7 libraries. To conduct the study, we used the drug “Heptral”, enteric-coated tablets, 500 mg, the pharmaceutical substance ademethionine 1,4-butanedisulfonate and excipients.
Results
A chemometric model based on independent component analysis is proposed. The model includes an optimization procedure for selecting the optimal number of independent components and accounts for the effect of spectral transformations on the predictive performance of the mathematical model. The metrological characterization methodology was assessed and all independent components and their relationship to characteristic frequencies were interpreted.
Conclusions
The possibility of using the independent component analysis in the quantitative ratio of ademethionine in tablets using IR-spectrometry in the total internal reflection distortion mode with preliminary chemometric processing of the analytical signal has been shown. The optimal parameters of the mathematical model were selected (number of components, type of coordinate line correction). The relative error of the resulting model is less than 1%.
Zitieren
APA
Kachalkina, I. V., Ryazanova, T. K., & Kachalkin, M. N. (2026). Application of IR-spectrometry and independent component analisys for the quantitative determination of ademethionine in tablets. Aspirantskiy Vestnik Povolzhiya, 26(2), 49-57. https://doi.org/10.35693/avp698869
Vancouver
Kachalkina IV, Ryazanova TK, Kachalkin MN. Application of IR-spectrometry and independent component analisys for the quantitative determination of ademethionine in tablets. Aspirantskiy Vestnik Povolzhiya. 2026;26(2):49-57. doi:10.35693/avp698869
BibTeX
@article{Kachalkina2026,
author = {Kachalkina, Irina V. and Ryazanova, Tatyana K. and Kachalkin, Maksim N.},
title = {Application of IR-spectrometry and independent component analisys for the quantitative determination of ademethionine in tablets},
journal = {Aspirantskiy Vestnik Povolzhiya},
year = {2026},
volume = {26},
number = {2},
pages = {49--57},
doi = {10.35693/avp698869}
}
EUVIMED