Case series: from ventilation failure to substitution success in occupational lead poisoning at a Korean indoor firing range
Annals of Occupational and Environmental Medicine · 09.02.2026 · 38 · e5
DOI: 10.35371/aoem.2026.38.e5 ↗Kurz gefasst
Fallbericht in der Zeitschrift Annals of Occupational and Environmental Medicine, online erschienen am 09.02.2026. Verfasst von Chul Gab Lee und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Occupational and Environmental Medicine, Chosun University Hospital, Gwangju, Korea. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background: Indoor firing ranges are globally recognized as high-risk settings for occupational and recreational lead exposure due to the use of lead-based ammunition and frequently inadequate ventilation systems. In Korea, however, public health surveillance and regulatory oversight have remained limited. This case series empirically demonstrates that in high-emission settings like indoor firing ranges, ventilation upgrades are insufficient. Source substitution with lead-free primer ammunition proved to be the only definitive intervention.Case presentation: In late 2023, an index case presenting with abdominal pain was found to have a blood lead level (BLL) of 55 μg/dL, prompting a government-mandated investigation. Nine male shooting instructors (tenure: 4–65 months) were subsequently identified with BLLs ranging from 38.2–73.2 μg/dL, while airborne lead concentrations (ALC) reached 0.51 mg/m³—10 times the occupational exposure limit (OEL: 0.05 mg/m³).During a 3-month closure to upgrade ventilation, workers received chelation therapy (CaNa₂EDTA and D-penicillamine), which reduced their BLLs to 3.2–25.7 μg/dL. However, 2 months after reopening, post-intervention ALC remained elevated at 0.0797 mg/m³, still exceeding the OEL, and BLLs rebounded to 16.2–53.3 μg/dL. A substitution strategy was then implemented, replacing lead-based ammunition with copper-clad, lead-free primer rounds. This intervention decreased ALC to
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Occupational and Environmental Medicine, Chosun University Hospital, Gwangju, Korea.
- Gwangju Branch of Korea Occupational Disease Surveillance Center, Gwangju, Korea.
Zitieren
APA
Lee, C. G., & Park, S. H. (2026). Case series: from ventilation failure to substitution success in occupational lead poisoning at a Korean indoor firing range. Annals of Occupational and Environmental Medicine, 38, e5. https://doi.org/10.35371/aoem.2026.38.e5
Vancouver
Lee CG, Park SH. Case series: from ventilation failure to substitution success in occupational lead poisoning at a Korean indoor firing range. Annals of Occupational and Environmental Medicine. 2026;38:e5. doi:10.35371/aoem.2026.38.e5
BibTeX
@article{Lee2026,
author = {Lee, Chul Gab and Park, Soo Hyeong},
title = {Case series: from ventilation failure to substitution success in occupational lead poisoning at a Korean indoor firing range},
journal = {Annals of Occupational and Environmental Medicine},
year = {2026},
volume = {38},
pages = {e5},
doi = {10.35371/aoem.2026.38.e5}
}
EUVIMED